FABRICATOR 210
Manual No. 0-4855
5-3
SERVICE
5.02 Basic Troubleshooting
The basic level of troubleshooting is that which can be performed without special equipment or knowledge, and
without removing the covers from the Power Supply.
If major components are faulty, then the Power Supply should be returned to an Accredited Thermal Arc Service Agent
for repair.
5.03 Solving Problems Beyond the Welding Terminals
The general approach to fix GMAW/FCAW problems is to start at the wire spool then work through to the MIG torch.
There are two main areas where problems occur:
Porosity
When there is a gas problem the result is usually porosity within the weld metal. Porosity always stems from
some contaminant within the molten weld pool which is in the process of escaping during solidification of the
molten metal.
Contaminants range from no gas around the welding arc to dirt on the work piece surface. Porosity can be
reduced by checking the following points:
FAULT
CAUSE
REMEDY
1. Gas cylinder
contents and flow
meter
a. Ensure that the gas cylinder is not empty
and the flow meter is correctly adjusted to
25CFM (15 litres per minute)
2. Gas leaks
a. Check for gas leaks between the
regulator/flow meter connection and in
the gas hose to the power supply
3. Internal gas hose in
the power supply
a. The hose from the solenoid valve to the
MIG torch adaptor may be fractured or
disconnected from the MIG torch adaptor.
Return to an Accredited Thermal Arc
Service Agent for repair.
4. Welding in a windy
environment
a. Shield the weld area from the wind or
increase the gas flow
5. Welding dirty, oily,
painted, oxidized or
greasy plate.
a. Clean contaminates off the plate
6. Distance between the
MIG torch nozzle and
the work piece.
a. Keep the distance between the MIG torch
nozzle and the work piece to a minimum.
7. Maintain the MIG
torch in good
working order.
a. Ensure that the gas holes are not blocked
and gas is exiting out of the torch nozzle.
Refer to WARNING below
b. Do not restrict gas flow by allowing
spatter to build up inside the MIG
torch nozzle.
C. Check that the MIG gun O-rings are not
damaged.
Porosity
Table 5-1: Porosity Problems
Содержание FABRICATOR 210
Страница 6: ......
Страница 22: ...FABRICATOR 210 INTRODUCTION 2 6 Manual No 0 4855...
Страница 38: ...FABRICATOR 210 INSTALLATION 3 16 Manual No 0 4855 NOTES...
Страница 54: ...FABRICATOR 210 OPERATION 4 16 Manual No 0 4855 NOTES...
Страница 62: ...FABRICATOR 210 SERVICE 5 8 Manual No 0 4855 NOTES...
Страница 67: ......
Страница 70: ......