ix
INTRODUCTION
Flammable hair preparations should not be used by persons
intending to weld or cut.
Allow work and equipment to cool before handling.
NOISE
can cause permanent hearing loss.
Wear proper protective ear muffs or plugs.
Make sure others in the operating area are protected from noise.
Comply with the precautions in this manual and those detailed in
CGA Standard P-1, SAFE HANDLING OF COMPRESSED
GASES IN CYLINDERS.
Pressure Regulators:
Regulator relief valve is designed to protect only the regulator
from overpressure and not intended to protect any downstream
equipment. Provide such protection with one or more relief
devices.
Never connect a regulator to a cylinder containing gas other than
that for which the regulator was designed.
Remove faulty regulator from service immediately for repair
(first close cylinder valve) if gas leaks externally, if delivery
pressure continues to rise with downstream valve closed, or if
gauge pointer does not move off stop pin when pressurized, nor
returns to stop pin after pressure release.
Do not attempt to repair faulty regulators. Send to manufactur-
er’s authorized repair center where special techniques and tools
are used by trained personnel.
Cylinders must be handled carefully to prevent leaks and dam-
age to walls, valves, or safety devices.
Contact with electrical circuits including third rails, electrical
wires, or welding circuits can product short circuit arcs that may
lead to a serious accident.
ICC or DOT markings must be on each cylinder as an assurance
of safety when the cylinder is properly handled.
Use only cylinders with name of gas clearly marked on them; do
not rely on color to identify gas content. Notify supplier if
unmarked. Never deface or alter name, number or other mark-
ings on a cylinder.
Keep valves closed on empty cylinders, replace caps securely,
mark MT, keep separate from full cylinders and return promply.
Never use a cylinder or contents for other than intended use.
Never use as a support or roller.
IMPORTANT SAFETY PRECAUTIONS (continued)
Fire and Explosion
(continued)
Noise
High Pressure
Gas Cylinders
Содержание 400 GTSW AC/DC
Страница 2: ......
Страница 46: ...OPERATION 28 NOTES ...