42
10.0 VOLTAGE REDUCTION DEVICE (VRD)
10.01 VRD Specification
Description
Pro-Lite
250S
Notes
VRD Open Circuit Voltage
15.3 to 19.8V
Open circuit voltage between welding
terminals
VRD Resistance
148 to 193 ohms
The required resistance between welding
terminals to turn ON the welding power
VRD Turn OFF Time
0.2 to 0.3 seconds The time taken to turn OFF the welding
power once the welding current has
stopped
10.02 VRD Maintenance
Routine inspection and testing (power source)
An inspection of the power source, an insulation resistance test and an earth resistance test
shall be carried out.
a)
For transportable equipment, at least once every 3 months; and
b)
For fixed equipment, at least once every 12 months.
The owners of the equipment shall keep a suitable record of the periodic tests.
Note 7
A transportable power source is any equipment that is not permanently connected and
fixed in the position in which it is operated.
In addition to the above tests and specifically in relation to the VRD fitted to this machine,
the following periodic tests should also be conducted by an accredited Thermal Arc service
agent.
Description
IEC 60974-1 Requirements
VRD Open Circuit Voltage
Less than 20V; at Vin=208-230V or 460V
VRD Turn ON Resistance
Less than 200 ohms
VRD Turn OFF Time
Less than 0.3 seconds
If this equipment is used in a hazardous location or environments with a high risk of
electrocution then the above tests should be carried out prior to entering this location.
Содержание 250S DC CC
Страница 2: ......
Страница 4: ...4 PAGE LEFT INTENTIONALLY BLANK ...
Страница 22: ...22 PAGE LEFT INTENTIONALLY BLANK ...
Страница 36: ...36 PAGE LEFT INTENTIONALLY BLANK ...
Страница 50: ...50 APPENDIX A INTERCONNECT DIAGRAM ...
Страница 51: ...51 ...
Страница 53: ...53 Figure 11 Location of PCB WK 4921 ...