12 |
P a g e
Troubleshooting
Be sure to check these items first:
x
Is there a power outage in the area?
x
Is the household fuse blown or the circuit breaker
tripped?
x
Is the appliance properly connected to the electrical
supply?
Many problems can be resolved without the need for a
service call. See the following list as a reference of
possible solutions of simple problems.
Symptom
Possible Cause
Potential Remedy
Appliance is not cooling.
Appliance has been switched off.
Check display to make sure the unit is
not switched off. If
display reads “OFF”
,
simultaneously press and hold LOCK
and WARMER to return to operating
mode.
The compressor is constantly
running or running too much.
Appliance opened frequently.
Do not open the appliance
unnecessarily.
The ventilation openings have been
covered.
Remove obstacles at the ventilation
openings located at the base of the unit
and in the refrigerator interiors.
A large amount of product, or warm
product was placed into the appliance.
The compressor will run more than
normal until the product cools. The
more that is added, the longer the motor
will run.
Excessively warm environment.
Avoid placing the unit in direct sunlight,
or near a heat source. If the appliance is
in an unusually warm environment, the
compressor will run more.
Leveling legs are not extended.
Extend the leg height to improve air
circulation. This will reduce the amount
of time the compressor needs to run.
Door gasket is not sealing.
Inspect the condition of the gasket. If
damaged, cold air can escape the
cabinet and cause the compressor to
run more than normal.
Products and beverages in the unit
are too cold.
Temperature has been set too low.
Increase the temperature. See
“
Setting
the temperature
”.
Product placed too close to ventilation
holes.
Rearrange the bottles, so that nothing
obstructs the interior ventilation holes.
Содержание T24UW800LP