FINAL CHECK LIST

Cooktop correctly positioned
and anchored in countertop re-
cess.

Specified clearances maintained
to cabinet surfaces.

Unit Level – front to back – side
to side.

Burner caps positioned prop-
erly on sealed burner bases.

All packaging material removed.

Backguard attached (if horizon-
tal clearance to combustible ma-
terials behind cooking surface
is less than 12").

The stainless steel radiant and
porcelain grill grate is in place.

The griddle plate is correctly
positioned and leveled.

INSTALLER  CHECKLIST

OPERATION

All internal packing materials
removed. Check below grates
and grill pans.

Burner caps properly seated
into burner bases.

Grill components properly
seated (not all models). Refer
to Care & Use Manual for Grill
details.

Bezels centered on burner
knobs, and knobs turn freely.

Each burner lights satisfacto-
rily, both individually and with
other burners operating.

Air Shutter adjustment for
proper flame made for Grill and
Griddle. See  Fig. 15.

Griddle is level or tilted slightly
forward and does not rock (not
all models).

Burner grates correctly posi-
tioned, level, and do not rock.

GAS SUPPLY

Connection: 3/4" NPT with a
minimum 3/4" diameter flex line.

The appliance is connected only
to the type of gas for which it is
certified for use.

The pressure regulator (shipped
with unit) has been connected
to the manifold and is set for 5"
W.C. for natural gas or 10"
W.C. for propane.

Manual gas shut off valve in-
stalled in an accessible location
(without requiring removal of
appliance).

Unit tested and free of gas leaks.

Gas supply pressure does not
exceed 14" W.C.

ELECTRICAL

Polarized and grounded
120VAC, 15 Amp receptacle
with 15 Amp over-current pro-
tection is provided for service
cord connection.

STEP 7:  Test and Adjustment

CAUTION

Thermador recommends that burner
adjustments be made by a qualified
technician at the time of installation.
Extreme care should be used when
adjustments are made after installa-
tion. Improper or lack of adjust-
ments may void your warranty.

Install any loose components, such as burner caps and grates, that may have
been removed earlier. Before testing operation of the appliance, verify that
the unit and the gas supply have been carefully checked for leaks and that
the unit has been connected to the electric power supply. Turn the manual
gas shut-off valve to the open position. Check operation of the sealed gas
burners, griddle and grill by pushing and turning each knob counterclock-
wise to HI. The burner igniters will click until the flame ignites. The two far
left sealed burners feature XLO™, causing the flame to cycle on and off
when the knob is set to the XLO™ range. This is normal operation.
Burner flames should be blue and stable with no yellow tips, excessive noise,
or lifting of the flame from the burner. If any of these conditions exist, check
that the air shutter (grill and griddle only) or burner ports are not blocked
or clogged. Remove any blockages that exist.

If the flame is too yellow, indicating insufficient air, adjust the shutter
counterclockwise to increase air inlet (grill and griddle only).

The sealed top burner flames and griddle should be approximately 1-1/2"
high. The grill burner flames should be 1/2" to 1". (See Fig. 13).

NOTE: 

No air shutter or low flame adjustment is necessary or possible

with the sealed top burners.

For the most up to date critical installation
dimensions by fax, use your fax handset and
call 702/833-3600.  Use code #8030.

United States for use in Canada.  Check
with your local Canadian distributor or
dealer.  Thermador, 5551 McFadden Avenue,
Huntington Beach, CA 92649.

 

Fig. 13 - Proper Flame 

(Approx.)

Sealed

Burners

1

-1

/

2

"

1

/

2

 

to

 1"

Grill

and

Griddle

Содержание Professional P24WK

Страница 1: ...SIONAL COOKTOPS 24 MODEL P24WK 36 MODELS PSC364GD PSC364GL PSC366 48 MODELS PSC484GG PSC486GD PSC486GL PSC484WK PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING CET MANUEL CONTENIT AVERTISSEMENTS EN...

Страница 2: ...appliance is correct for the type of gas being provided Refer to Step 4 before proceeding with the installation WARNING Improperinstallation adjustment alteration serviceormaintenance cancauseinjuryor...

Страница 3: ...se a hood that is wider than the cooktop cooking surface This may be particularly beneficial for those cases such as a long duct run or heavy usage of the grill in which improved capturing of the cook...

Страница 4: ...m of an unprotected cabinet A 30 inch minimum distance is necessary when the bottom of the wood or metal cabinet is protected by not less than 1 4 inch of a flame retardant material covered with not l...

Страница 5: ...dard 24 Deep Base Cabinet Control Panel Projecting 1 3 8 from Base Cabinet Face 2 Control Panel Flush to Cabinet Face Min 25 3 8 Deep Base Cabinet Required 36 Min to Combustible Material from Cooking...

Страница 6: ...used 2 Notch Depth 26 3 8 22 5 8 23 3 8 2 3 4 7 3 4 12 1 2 Countertop 3 TO CENTERLINE GAS INLET Cabinet face for installation with projecting control panel Cabinet face for installation with flush co...

Страница 7: ...off Valve STEP 2 Cabinet Preparation 3 4 NPT Inlet 3 4 NPT Outlet Gas Flow Fig 9 3 Min 36 Power Cord 3 4 flex line 3 Prong grounding type receptacle connected to a properly grounded and polarized elec...

Страница 8: ...or tilted slightly forward and IMPORTANT Verify that the appliance is correct for the type of gas being provided Refer to Step 4 before proceed ing with the installation Attach the backguard be fore...

Страница 9: ...ure de gaz aux pressions d epreuve egale a ou au moins que 1 2 psig 3 5 kPa L appareil et sa soupape d arret individual doivent etre deconnectes du systeme de tuyauterie de la fourniture de gaz pendan...

Страница 10: ...round ing In the absence of these codes or ordinances observe National Electrical Code ANSI NFPA No 70 Current Issue See Fig 13 for recommended grounding method Anelectricalwiringdiagramand schematic...

Страница 11: ...ntainchemicalswhichcouldproveharm ful Rinse with water after exposure and wipe dry with a clean cloth LOW BACK AND ISLAND TRIM MODEL NUMBERS COOKTOP MODEL NO 12 LOW BACK Island Trim P24WK GP24LBS GP24...

Страница 12: ...s not exceed 14 W C ELECTRICAL Polarized and grounded 120VAC 15 Amp receptacle with 15 Amp over current pro tection is provided for service cord connection STEP 7 Test and Adjustment CAUTION Thermador...

Отзывы: