Page. 27
Installer checklist
Final check
Gas supply
Electrical
Operation
Clean and protect exterior surfaces
•
Always wipe in the direction of the stainless steel
grain.
•
To condition and protect stainless steel, use the
Thermador Stainless Steel Conditioner, which can be
purchased in the Thermador eShop (thermador.com/
customer-care).
•
DO NOT
allow deposits to remain for long periods of
time.
•
DO NOT
use ordinary steel wool or steel brushes.
Small bits of steel may adhere to the surface causing
rust.
•
DO NOT
allow salt solutions, disinfectants, bleaches
or cleaning compounds to remain in contact with
stainless steel for extended periods. Many of these
compounds contain chemicals which could prove
harmful. Rinse with water after exposure and wipe dry
with a clean cloth.
•
Refer to the Use and Care Guide for additional
information.
Troubleshooting
See Use and Care Guide for troubleshooting information.
Specified clearances maintained to cabinet
surfaces.
Unit level – front to back – side to side.
Burner caps positioned properly on burner bases.
All packaging material removed.
Kick panel in place and screws secure.
Verify flame at each burner. Flame may need to
burn for several minutes to remove impurities from
the gas lines.
Verify that the ExtraLow
®
feature works and relights
around the entire burner.
INSTALLER:
Leave the Home Connect™ instruction
leaflet with the owner of the appliance. In order to
utilize the full feature potential of the appliance, the
owner should download the Home Connect™ app
on their smart device and pair the appliance to the
home's Wi-Fi device.
Gas Connection: ¾'' (19 mm) N.P.T. with a min. ¾''
(19 mm) diameter flex line.
The appliance is connected only to the type of gas
for which it is certified for use.
Manual gas shut off valve installed in an accessible
location (without requiring removal of range).
Owner is aware of location of the gas shut-off valve.
Unit tested and free of gas leaks.
If used on propane gas, verify that the propane gas
supply is equipped with its own high pressure
regulator in addition to the pressure regulator
supplied with the appliance.
Gas supply pressure does not exceed 14'' W.C.
(34.9 mb).
Receptacle with correct over-current protection is
provided for service cord connection.
Proper ground connection.
Owner is aware of location of the main circuit
breaker.
Bezels centered on burner knobs, and knobs turn
freely.
Each burner lights satisfactorily, both individually
and with other burners operating.
Oven door hinges seated and hinge locks in proper
position. Oven handle and door is level and
centered. Door opens and closes properly.
Burner grates correctly positioned, level, and do not
rock.
INSTALLER:
Write the model number and serial
number in the Use and Care Guide. Leave the Use
and Care Guide and Installation Manual with the
owner of the appliance.