Installation Instructions English 4
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
Gas Type Verification
Verify that the appliance is correct for the type of gas
provided at installation location. Ensure that the appliance
is connected to the type of gas for which it is certified.
Before proceeding with the installation refer to
“STEP 6:
Gas Requirements and Hookup” on page 16
for
specifications.
All models are certified for use with natural gas. Field
conversion of the appliance for use with propane gas
supply will require installation of conversion kit, supplied
with the range (service number 00553182). Only a qualified
service technician or installer should make this conversion.
See
LP Conversion Kit Instruction
for full installation
information.
Gas Supply
Natural Gas
– 6'' water column (14.9 mb) min., 14''
(34.9 mb) maximum
Propane Gas
– 11'' water column (27.4 mb) min., 14''
(34.9 mb) maximum
Electric Power Supply
See
“STEP 7: Electrical Requirements, Connection &
Grounding” on page 18
for specifications.
Check local building codes for the proper method of
appliance installation. Installation, electrical connections
and grounding must comply with all applicable codes. Local
codes vary and it is the responsibility of the installer to
ensure installation is in accordance with these codes. In the
absence of local codes the appliance should be installed in
accordance with the National Fuel Gas Code ANSI Z223.1/
NFPA 54 current issue and National Electrical Code ANSI/
NFPA 70-current issue. In Canada, installation must be in
accordance with the CAN 1-B149.1 and .2 – Installation
Codes for Gas Burning Appliances and/or local codes.
Safety Codes and Standards
This appliance complies with the following standards:
•
UL 858, Standard for the Safety of Household Electric
Ranges
•
ANSI Z21.1, American National Standard for
Household Cooking Gas Appliances
•
CAN 1-1. 1-M81, Domestic Gas Ranges
•
CAN/CSA-C22.2 No. 61, Household Cooking Ranges
It is the responsibility of the owner and the installer to
determine if additional requirements and/or standards
apply to specific installations.
IMPORTANT:
When installing against a combustible surface, a Low
Backguard is required. A THERMADOR
TM
Low Backguard
must be purchased separately. See
“STEP 8: Backguard
Installation (optional)” on page 20
for backguard and
installation information.
When using the Flush Island Trim, THERMADOR
recommends a minimum 12'' (305 mm) rear clearance to a
combustible surface (
see “Installation Clearances” on
page 7
). Clearances from non-combustible materials are
not part of the ANSI Z21.1 scope and are not certified by
CSA. Clearances of less than 12'' (305 mm) must be
approved by the local codes and/or by the local authority
having jurisdiction.
Refer to
Table 3, “Backguard Kit Model Numbers,” on
page 20
, for the correct backguard models that are
designed for this range. After selecting the correct
backguard, the range must be installed properly, using the
minimum clearances to combustible surfaces specified in
“STEP 2: Cabinet Preparation” on page 6
.
WARNING
State of California Proposition 65 Warnings:
This product contains chemicals known to the State of
California to cause cancer, birth defects or other
reproductive harm.
WARNING
To avoid possible burn or fire hazard, a backguard
designed specifically for this range must be installed
whenever the range is used.
CAUTION
To eliminate risk of burns or fire caused by reaching over
heated surface units, cabinet storage located above the
surface units should be avoided.