Service Manual for Thermador Pro Grand Dual Fuel Ranges:
PRD304EG,
PRD364EDG, PRD364EDPG, PRD364ELG, PRD366EG, PRD366EPG, PRD484ECG, PRD484EEG, PRD486EDG, PRD486EDPG, PRD486ELG
58300000157422_ARA_EN_A
Page 72 of 95
4. At the back of the range, detach the wire connectors, and make a
note of which wires are connected to each of the two different
terminals (see Figure 140, page 72).
NOTE:
It is always recommended to label and tag all wires, wire
connectors and harnesses prior to disconnecting them, so as to
correctly identify their connections/locations when re-assembling.
Alternatively, you can photograph the wire connections prior to
disconnecting (for example, with your mobile phone).
5. Remove and retain the screws that secure the cooling fan
mounting plate onto the range chassis (see Figure 139).
6. Using gloves, remove the cooling fan.
7. Replace the cooling fan if needed.
Figure 140: Typical Cooling Fan
1
Wire connectors (2)
4.6.6.1
Air Interlock Switch Removal and Replacement
The air interlock switch can be removed and replaced independently
of the cooling fan.
Be sure to check QuickFinder for relevant information, documentation,
and the correct part number when replacing this component.
Figure 141: Air Interlock Switch
Figure 142: Bracket
1. Follow all safety precautions and steps in
2. Remove the backguard, per
Backguard and Island Trim Removal
procedure, page
.
3.
Remove back panel, per
Back Panel Removal and Replacement
procedure, page
4. At the cooling fan, remove and retain the nuts securing the air
interlock switch onto its bracket (see Figure 141, Figure 142, and
Figure 143, page 73).
5. Replace the air interlock switch if needed.