Page 4
CONTROL PANEL
PHE ELECTRONIC TOUCH
CONTROL - shown in Fig 1.
A. Motor OFF button
B. ON button and motor speed
selection button 1, 2, 3, 1,....
C. Speed 1LED
D. Speed 2 LED
E. Speed 3 LED
F. Timer LED
G. Timer.
If the motor is off while the
timer is pressed the motor will
run at speed 3 for 20 minutes
then stop.
If the motor is running when
the timer key is pressed the
motor will continue to run for
10 minutes. After 10 minutes
the motor will stop.
Pressing the timer or speed
button while the Timer LED is
on will disable the timed mode.
H. Light ON/OFF button.
I. Dim Light ON/OFF button.
Fig. 1
F
Grease Filter Saturation
LED
The
flashing LED
marked
D
reminds you when the grease
filter needs to be cleaned after
40 hours use. Follow the
instructions for cleaning filters
in this booklet. Once the grease
filters have been cleaned, reset
reminder by pressing button
A
for about 3 seconds until you
hear the signal (beep); the
LED D
will now stop flashing.
Circuit Self-test
The control allows the user to
perform a self-test to check the
correct function of the hood. The
self test is activated by pressing
the
A
and
B
keys (Figure 1)
simultaneously for 3 seconds.
The self-test procedure order is:
1. Four LED’s switch on.
2. Four LED’s switch off.
3. Blower runs at speed 1.
4. Blower runs at speed 2.
5. Blower runs at speed 3.
6. Blower off.
7. Lights switch on.
8. Lights dim.
9. Lights turn off.
10. Beep signals end of self-test.
A
E F
C
D
G
H
I
B