English 7
Maxitrol regulator conversion:
•
Remove conversion cap with a 7/8” socket or wrench.
•
Snap-out stem from bottom of the cap, flip stem over to
show “
LP
” end, and snap stem back into the cap, as
shown.
•
Re-install conversion cap —configured for LP gas—
back into top of the Maxitrol regulator.
Setting Manual Valve Screws
for the Star
®
Burners
Screw driver for valve screw setting:
A precision screwdriver with high-strength blade, similar to
the *Wiha no. 26033, with 1/8" [3.0mm] wide, .020"
[0.50mm] thickness tip, shown below, should be used to
reposition the bypass screws for minimum flow settings on
manual valves.
*Used by permission from Wiha Quality Tools division of Willi
Hahn Corporation USA.
Flip Stem
Valve Screw