7. Install the two cable holders into the blower housing.
8. Pass the cable connector under the holders and secure
them.
A
A
A
B
C
D
A. Hood drawer installation screws
B. Plastic cable holder
C. Cable holder screws
D. Drawer connector
9. Plug the wire connector assembly supplied with the
blower housing to the mating cable connector from the
range hood.
Connect Vent System
1. Fit vent system over the exhaust outlet.
2.
Measure from the bottom of the air delector to the
bottom of the hood outlet. Cut the ductwork at the
measured dimension.
Dimension
to measure
Roof
outlet
Wall
outlet
3. Seal connection with clamps.
Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
•
Disconnect power.
•
Remove terminal box cover.
•
Remove the knockout in the terminal box cover and
install a UL listed or CSA approved 1/2” strain relief.