background image

Page 1

READ AND SAVE THESE INSTRUCTIONS

WARNING - TO REDUCE THE RISK

OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS,
OBSERVE THE FOLLOWING:

CAUTION:  FOR GENERAL

VENTILATING USE ONLY.  DO
NOT USE TO EXHAUST
HAZARDOUS OR EXPLO–SIVE
MATERIALS OR VAPORS

.

A. Use this unit only in the manner

intended by the manufacturer.  If
you have questions, contact the
manufacturer.

B. Before servicing or cleaning the

unit, switch power off at service
panel and lock service panel
disconnecting means to prevent
power from being switched on
accidentally.  When the service
disconnecting means cannot be
locked, attach a tag to the service

IMPORTANT SAFETY INSTRUCTIONS

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.

INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.

IMPORTANT:

 Save these Instructions for the Local Electrical Inspector’s use.

INSTALLER:

 Please leave these Instructions with this unit for the owner.

OWNER:

 Please retain these instructions for future reference.

Safety Warning: Turn off power circuit at the service entrance and

lock-out panel, before wiring this appliance.

Requirement: 120 V AC, 60 Hz. 15 Amp branch circuit (Appliance Rating see Table 1)

L933C  Ed. 05/98

panel to indicate power has been
switched off for maintenance.

C. Installation Work and Electrical

Wiring Must Be Done By Qualified
Person(s) In Accordance With All
Applicable Codes & Standards,
Including Fire-rated Construction.

D. Sufficient air is needed for proper

combustion and exhausting of
gases through the flue (chimney)
of fuel burning equipment to
prevent back- drafting.  Follow the
heating equipment manufacturers
guideline and safety standards
such as those published by the
National Fire Protection Assoc-
iation (NFPA), the American
Society for Heating, Refrigeration
and Air Conditioning Engineers
(ASHRAE), and the local code
authorities.

INSTALLATION INSTRUCTIONS

 WALL HOOD SERIES:

HDW, HSW, HCSW, HGSW, HTSW

FOR RESIDENTIAL USE ONLY

NOT TO BE INSTALLED OVER GAS GRILLS

Содержание HCSW

Страница 1: ...n Beach CA 92649 800 735 4328 ECO 71589 35 05 017F BSH Home Appliances Corp 1997 Litho in Italy 10 01 READ AND SAVE THESE INSTRUCTIONS CARE AND USE FOR WALL HOODS Turn Book Over for Installation Instr...

Страница 2: ...turn hood ON when cooking on high heat or when flamb ing foods IMPORTANT SAFETY INSTRUCTIONS 3 Clean ventilating fans frequently Grease should not be allowed to ac cumulate on fan or filter 4 Use prop...

Страница 3: ...est n cessaire Chauffer l huile lentement sur un positionnement bas moyen 4 Ne pas laisser la cuisini re sans surveillance pendant la cuisson 5 Utiliser toujours les batteries de cuisine et les usten...

Страница 4: ...filtersinthisbooklet Once thegreasefiltershavebeencleaned reset reminder by pressing button A for about 3 seconds until you hear the signal beep the LED D will now stop flashing MODELS HGSW MECHANICAL...

Страница 5: ...cool If new lights do not operate check fuses see page 7 Fuses and be surelightsareinsertedcorrectlybefore calling service OPERATING INSTRUCTIONS HOOD The blower should be turned on for about 5minute...

Страница 6: ...SW HCSW36 42 Fig 3 Unscrew the light cover Remove the damaged light and replace with a new 12 Volt 20 Watt maximum halogenlightmadefora G 4 base Follow package directions and do not touch new light wi...

Страница 7: ...Page 7 Fig 7...

Страница 8: ...For All repair labor and replacement parts found to be defective due to materials and workmanship Service must be provided by a Factory Authorized Service Agency during nor mal working hours For a Se...

Страница 9: ...ith this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at the service entrance and lock out panel before wiring this appliance Re...

Страница 10: ...vice pour indiquer que l alimentation a t coup e pour l entretien C Le Travail d Installation et de C blage lectrique Doit tre Fait Par les Personne s Qualifi es Conform ment Tous les Codes Normes App...

Страница 11: ...8 21 5 8 14 3 4 3 3 4 6 400 427 2 40W 220W 2 16A HSW30 37 25 5 8 33 42 1 2 30 20 1 4 14 3 4 3 3 4 6 400 310 2 18W 220W 2 A HSW36 42 25 5 8 33 42 1 2 36 20 1 4 14 3 4 3 3 4 6 400 310 2 18W 220W 2 A HTS...

Страница 12: ...ht run or as few elbows as possible CAUTION Vent unit to outside of building only 2 Use flex ducting only to connect rigid duct directly to transitions 3 COLD WEATHER installations should have an addi...

Страница 13: ...ll or using a stud finder Mark the center of the studs with a vertical line to the right and left of the marked fastener location Note Each 2 x 6 must span at least 2 studs side to side 7 Cutout drywa...

Страница 14: ...e a gap of 1 minimum between top of transition and sheet metal duct and cover gap with a starting collar wrapped around duct and transition Locate collar screws so they fit into corner of duct cover S...

Страница 15: ...anel Check lights and blower operation per Care Usesectionofthismanual Install filters 6 Install duct cover per Fig B Make sure to leave this manual for the home owner Alternate reduced ceiling height...

Страница 16: ...ed 1 4 below the ceiling The resulting space on top of the chimney can be filled with a 1 4 thick piece of plywood cut to theinsidecrosssectionofthechimney cover and finished to match the ceiling Copy...