ERROR CODES
H01
The power input voltage is too low
H02
The power input voltage is too high
H03
System operation failed (e�g�: no arc pressure)
H04
Missing nozzle or electrode
H05
During the pilot arc, the electrode is not separated from the nozzle
(check the electrode free movement)
H06
Over-temperature alarm
H07
Over-current alarm
H08
Torch inspection / cap sensor
H10
Air pressure alarm
H11
Missing phase