Install “P” trap on outlet connection 

of tank. (Note: the unit already has 

an internal gas trap).

DONʼT . . .

Reduce pipe size on outlet piping.

DO . . .

Allow a minimum of 14” clearance from 

top of tank for removal of unit lid.

READ instruction manual included with 

system before doing anything.

Install unit allowing for the minimum 

clearances shown.

Make sure the height above the

Internal  Strainer  Access  Cover  is 

enough to remove the strainer.

Make piping connections with rubber 

“No Hub” connectors (provided).

Keep outlet piping as straight as pos-

sible. Use only “sweep” connections.

Install vent on outlet piping.

Fill the tank with water before ener-

gizing  the  power  to  the  motor  and 

heater.

Set Programmable Time Controller for 

proper operating times.

INSTALLATION  INFORMATION

Note

Installations must comply with 

all applicable local, state, and 

national codes for your area.

Suggested Minimum Footprint Dimensions

W-250-IS Specifications

4”

8.75”

8.75”

7”

4”

6”

6”

25.5”

Job Specification:

Grease and oils separator(s) shall be Thermaco 

Big Dipper

 automatic grease/oil recovery system(s) as manufac-

tured by Thermaco, Inc., Asheboro, North Carolina as noted on plans.

Separator Specifications:

Furnish and install ___ Thermaco 

Big Dipper

 Model No. W-250-IS, bright finish type 304 stainless steel exterior, 

rotationally molded polyethylene interior automatic self-cleaning grease and oil recovery separator(s) for floor mounted 

or partially recessed installation, rated at 25 gallons per minute peak flow, 50 pounds of grease capacity and includ-

ing as an integral part of the unit, 1 rotating gear hydrophobic wheel assembly for automatic grease/oil removal, an 

integral flow control device, self-regulating enclosed electric immersion heater, a vessel vent, an integral gas trap, an 

integral programmable 24-hour multi-event time control, a field reversible motor location, a field reversible grease/

oil sump outlet, quick release stainless steel lid clamps, a gasketted and fully removable 304 stainless steel lid, a 

hinged lift-out strainer basket access, an internal stainless steel strainer basket for collection of coarse solids, and a 

separate grease and oils collection container.  Electric assembly shall be tested to comply with pertinent sections of 

the Standards for Safety ANSI/UL 73 and/or ANSI/UL 1004.  Electric motor shall be equipped with thermal overload 

protection with automatically resettable switch.  Two (2) no-hub connectors for plumbing connection provided.