The  Thermaco, Inc. Big Dipper

®

 Automatic Grease and Oils 

Removal System removes free-floating grease & oils from kitchen 

drain water flows.  As most food service facility managers already 

know, grease buildup within a building’s plumbing drainage system 

is a major cause of problems due to drain line blockages.  These 

problems jeopardize normal operations as well as create health 

and safety hazards within the facility itself.

The proper installation of a Big Dipper System can reduce or eliminate grease problems.  Use 

of the Big Dipper assures minimization and/or elimination of costly sewer surcharges and fines 

through efficient separation and removal of free-floating grease & oils.  In addition, the Big Dipper 

also helps reduce or eliminate pumping and disposal costs associated with conventional grease 

traps or interceptors.  The recovered grease & oils are substantially water-free and are suitable 

for recycling by local rendering and/or biodiesel companies.

The Big Dipper system is an automatic, self-cleaning device.  As greasy kitchen effluent drains 

from kitchen fixtures, the unit traps the grease & oils.  These separate from the effluent and rise 

to the surface of the separator tank.  The unit automatically skims the trapped grease & oils and 

transfers the grease & oils to a collection container.  A timer controls the self cleaning operation, 

activating the skimming wheel at a user-set time.  Only the “cleaned” water exits the unit and 

flows into the facility drain lines.  

Incidental food solids less than 1.5” (38 mm) in diameter are separated and flushed out of the 

system automatically by the Automatic Solids Transfer component.  These incidental solids are 

typical of those that are rinsed off of plates before going to a dishwasher.  The Eductor Pump of 

the AST is not designed to handle non-food products such as plastic, rubber or metal items.

The Big Dipper system’s compact footprint allows installation directly at the source, where grease 

problems originate.  The system design also allows easy maintenance and operation requiring only 

a minimal amount of daily and weekly maintenance to maintain peak operating performance.

The Big Dipper system design allows for maximum installation flexibility.  Reversing the system 

operation is as simple as rotating the cover assembly of the unit.

Grease interceptors, grease traps, automatic recovery units, grease removal devices and other 

similar plumbing devices receiving kitchen flows from sinks, floor drains, woks and other food 

bearing sources may generate odors.  There are many factors influencing odor evolution and dis-

semination.  These include room ventilation, kitchen menu, ambient temperatures, ware washing 

practices, grease/oil input, daily input fluid volume, sanitizers, installation plumbing design and 

product maintenance/upkeep.  Odors are usually prevented by good area ventilation, frequent 

fluid inputs, good product maintenance practices and proper product installation.  Additional steps, 

including aeration, chlorination, improved area ventilation and additional maintenance control, 

may be needed at some sites.

Big Dipper

®

 Automatic Solids Transfer

(AST) System Overview

Содержание Big Dipper W-1250-AST

Страница 1: ...51 F 336 626 5739 E mail info thermaco com Online www big dipper com Installation Operation Instructions For Big Dipper W 750 AST and W 1250 AST Automatic Solids Transfer AST Series Units Including 23...

Страница 2: ...000 2 Table of Contents Table of Contents AST System Overview 3 AST System Maintenance 5 AST Timer Operation 6 AST System Troubleshooting 7 How To Reverse AST System Operation 8 Plumbing Installation...

Страница 3: ...kimming wheel at a user set time Only the cleaned water exits the unit and flows into the facility drain lines Incidental food solids less than 1 5 38 mm in diameter are separated and flushed out of t...

Страница 4: ...mer on the unit is no longer operating and should be replaced If pressing the button does nothing then there may be a problem with the motor assembly Please contact Thermaco or your local service agen...

Страница 5: ...cumulated solids Be sure to spray down both the inside and outside surfaces of the strainer assembly E Check the thickness of the grease layer at the top of the unit If there is more than a 1 2 12 mm...

Страница 6: ...r unit needs to be set for the proper automatic self cleaning operation for the facility The Big Dipper W 750 AST model is equipped with one 1 24 Hour 96 Event time controller while the W 1250 AST mod...

Страница 7: ...5 minutes per day There is a Power Indicator Light under the Timer which indicates that Power is reaching the unit If this light is not Red power is not reaching the unit 2 Remove the lid and clean aw...

Страница 8: ...UNPLUG UNIT BEFORE REMOVING LID SYSTEM WILL NOT OPERATE UNLESS CENTER LID LATCHES ARE FASTENED Note W 750 AST has one 1 module W 1250 AST has two 2 modules 1 Unlatch the Unit lid Pull the side wings o...

Страница 9: ...ope of 1 4 per foot 2cm per meter Use only sweep connections Don t reduce the pipe sizing on the outlet piping Don t install P trap on outlet connection of system Note The system already has a interna...

Страница 10: ...ht Greater Than 6 feet 1 95m For installations where there is a significant amount of head height More than 6 ft 1 95 m Thermaco Inc recommends installation of the optional VFCA Vented Flow Control mo...

Страница 11: ...controlled by a ground fault circuit breaker There is a Power Indicator Light that will glow Red if power is being fed to the unit If this light is off power is not reaching the unit This Big Dipper...

Страница 12: ...CK CONNECTOR FULLY INSULATED FEMALE CONNECTOR BLACK RED RED INTERCHANGE FULLY INSULATED QUICK CONNECTORS TO CHANGE HEATER OPERATING MODE RED WIRE TO THERMOSTAT GIVES SIMULTANEOUS HEATER MOTOR OPERATIO...

Страница 13: ...N WHITE BLACK WHITE WHITE BLACK BLACK WHITE WHITE WHITE POWER SUPPLY CORD BLACK BLACK FULLY INSULATED QUICK CONNECT PIGGY BACK CONNECTOR FULLY INSULATED FEMALE CONNECTOR BLACK RED RED INTERCHANGE FULL...

Страница 14: ...ensboro St Asheboro N C 27204 2548 Phone 336 629 4651 MNL ASTCU14000 14 Big Dipper AST System Wiring Diagram Junction Box Wiring Diagram For Big Dipper Model W 1250 AST POWER RING TERMINALS TO GROUND...

Страница 15: ...sheboro N C 27204 2548 Phone 336 629 4651 MNL ASTCU14000 15 Big Dipper AST System Electrical Components Safety Switch Part MSS 7 Motor Part M 58 Heater Part H 8 Thermostat Part TSTAT 4 Power Indicator...

Страница 16: ...el Wiper Assembly Part WWA 4 Skimming Wheel Assembly Part PDA 3 Wheel Drive Sprocket Part WDS 3 Big Dipper AST Lid Components With Wheel Cover Removed Wiper Blades 2 Part PB 3 Inlet Outlet Safety Swit...

Страница 17: ...itch Part ESHS 1 Big Dipper AST System Component Identification Big Dipper AST System Component Identification Rear Electrical Enclosure Assembly Part REEA 1 Timer Cover Part MTC 1 Wheel Cover Part MS...

Страница 18: ...125 FOR W 1250 AST LID GASKET PART RG 7 WIPER BLADES PART PB 3 W 750 AST requires two 2 W 1250 AST requires four 4 WHEEL WIPER ASSEMBLY PART WWA 4 WHEEL DRIVE SPROCKET PART WDS 3 SKIMMING WHEEL ASSEMB...

Страница 19: ...s Thermaco shall not be respon sible for damage to products resulting from vault flooding sewer line back up pumping or lift station failure ambient water flow or other sources of water damage This wa...

Отзывы: