Installation Instructions for 
Pre-hung Door Systems 
 

These installation instructions are designed to assist door installers who have 
an understanding of carpentry principles, and know how to properly and 
safely use power tools.  The purpose of these instructions is to illustrate how 
to install a Therma-Tru door system using methods and materials that help 
eliminate water related leaks.  If the directions are closely followed, the door 
system will have a long useful life with good resistance to rain related water 
intrusion problems. 
 
These methods are “tried and true” They are used widely by builders and 
remodelers who are serious about managing and keeping water outside the 
home. Rather than eliminate any steps that may be unclear to you, please call 
1-800-THERMATRU and ask for clarification.  If you remain unclear, please 
seek more professional assistance with the installation. 
 
Different parts of the country have different code requirements, which may 
not be covered in these instructions.  The installer is responsible for insuring 
the installation complies with local codes.  If you have unique code 
requirements that do not appear please contact 1-800-THERMATRU. 
 

Required Tools & Materials: 

2 & 6 foot Levels, Hammer, Putty Knives 

(firm & flexible), Framing Square, Caulking Gun, Sturdy Ladder, Shims, 
Tape Measure, High Quality Elastomeric or Polyurethane Sealant, Screw 
Gun/Drill -1/8 inch Drill Bit, Razor Knife, #2 & #3  Philips Bit, Stapler, 
Insulating Material, Eye Protection, Water Resistive Barrier, Flashing 
Material, #8 x 2-1/2 inch Exterior Grade Screws, & Optional Sill Pan. 

 

Read all instructions before starting. 

 

 

Therma-Tru Recommended Best Practices 

Use Water Resistive Barrier and Flexible Flashing: 

We recommend the use of a Water Resistive Barrier 
(WRB) applied to the exterior sheathing (OSB or 
other) and the use of an adhesive or flexible flashing 
product to seal around the opening.  The WRB should 
be cut in the opening (follow manufacturer’s 
guidelines) with the head of the flap taped up, to be 
sealed later in Step 11.  The flashing should be applied 
in an overlapping manner as shown, always working 
from the bottom up (follow manufacturer’s 
guidelines). 

 

 

 

 

 

 

Use a Sill Pan: 

We recommend you first “dry fit” the sill pan in the opening, 

following the instructions furnished with the sill pan.  Place the right and left 
sill pan ends tight against the sides of the opening.  Check the center section 
for proper length and if necessary, cut with a hack saw or tin snips.  Be sure to 
allow 2 inches of overlap at the joints. 
 

 

 

 

Note: 

Use only the PVC cement provided in the sill pan kit to glue the pieces   

together. The sill pan must be sealed to the sub-floor using an Elastomeric or 
Polyurethane sealant, but do not apply sealant to the bottom of the sill when 
using a sill pan. 

 

Step 1: Check Door Unit. 

 
Check width and height. 
 
Measure size of frame (width and height), not 
brickmould. 
 
Remove cleats and packaging, but keep door 
fastened closed with transport clip.  Do Not 
remove the transport clip until instructed to do 
so later in Step 7. 

 
 

 
 
 

 

Step 2: Check and Prepare Opening. 

 

Is the opening the correct size for the 
door unit? Check it against the door 
frame size now, before installation.  The 
opening should be frame height plus 1/2 
inch, and frame width plus 1/2 inch to 
3/4 inch. 

Fix any problems now. 

 

Are the framing and walls 

PLUMB

? Use 

a 6 foot level and check both sides of the 
opening, both ways (front to back and 
right to left). 

Fix any problems now.

 

 
Is the sub floor level and solid? 

Provide 

a flat, level, clean weight bearing 
surface so the sill pan or sill can be 
properly caulked and sealed to the 
opening. Scrape sand or fill as required. 
 

Note:

 If additional floor covering clearance is required, attach the shim board 

to the sub floor. Be sure to caulk well under the shim board. 
 
Is the opening square? Check all corners with a framing square.  Double check 
by comparing diagonal measurements.  

Fix any problems now. 

 

Содержание Pre-hung Door Systems

Страница 1: ...rrier and Flexible Flashing We recommend the use of a Water Resistive Barrier WRB applied to the exterior sheathing OSB or other and the use of an adhesive or flexible flashing product to seal around...

Страница 2: ...e jamb and on the bottom surface of the jambs and brickmould Note If a sill extender is used place a large bead of caulk at the junction of the extender and the sill approach Step 3 cont Caulking Back...

Страница 3: ...ole locations closest to the weatherstrip Close the door and carefully shim between the jamb and the opening behind the adjustable strike plate area Then open the door and drill 1 8 inch dia pilot hol...

Страница 4: ...o paint Doors Clean first with mild detergent and water or use a TSP tri sodium phosphate solution Rinse well and allow to dry completely Mask off hardware glass and remove weatherstripping before pai...

Страница 5: ...uctos adhesivos o de tapajuntas flexibles para sellar el per metro de la abertura Se debe cortar la WRB en la abertura siga las pautas del fabricante con el cabezal de la leng eta cubierta con cinta a...

Страница 6: ...mba y en la superficie inferior de las jambas y las molduras Nota si usa una extensi n para alf izar coloque un cord n de masilla de calafateo grande en la uni n de la extensi n y la entrada del alf i...

Страница 7: ...cios gu a de 0 32 cm de di metro e instale los tornillos largos para bisagra en las ubicaciones de orificio m s cercanas al burlete Cierre la puerta y coloque calzas cuidadosamente entre la jamba y la...

Страница 8: ...No aplique acabados bajo la luz solar directa Puertas de acero y Smooth Star Para pintar puertas primero limpie con un detergente suave y agua o use una soluci n de TSP fosfato tris dico Enjuague bie...

Отзывы: