background image

INSTALLATION  AND SAFETY GUIDELINES 

 

IMPORTANT 
 

Safe and  satisfactory  operation  of your  equipment  depends  on its  proper installation.  Installation  must 
conform  to local  codes, or in  the  absence of  local  codes with  the National  Fuel  Code ANSI Z223.1 (latest 
edition). 
All  THERMA-TEK  appliances  are shipped  with  a gas pressure  regulator  packed with  the  unit.   All  units  are 
adjusted,  tested,  and inspected  at the factory  prior  to shipment. 
After  uncrating,  immediately  check  the equipment  for visible  signs  of shipping  damage.   If  such  damage  has 
occurred,  do not refuse  shipment,  but  contact  the shipper  and file  appropriate  freight  claims. 
 

GENERAL 
 

 

Installation  of this  equipment  should  be made  by licensed  and authorized  personnel. 

 

A manual  gas shut-off  valve  must  be installed  in  the  gas supply  (service)  line  ahead of  the appliance 
and gas pressure  regulator  installed  in  the  gas stream  for  safety  and ease of  future  service. 

 

The  gas pressure  regulator  supplied  must  be installed  on the  appliance  prior  to connecting  the 
equipment  to the  gas line.   Failure  to install  a regulator  will  void  the  equipment  warranty  and result  in 
a potentially  hazardous  condition. 

 

The  appliance  and its  individual  shut  off  valve  must  be disconnected  from  the  gas supply  system 
during  any  pressure  testing  of that  system  in  excess  of ½ PSI. 

 

The  appliance  must  be isolated  from  the  gas supply  system  by closing  its  individual  shut  off  valve 
during  any  pressure  testing  of the  gas supply  piping  system  at test pressure  equal  to or less  than  ½ PSI. 

 

Please  contact  the  factory,  the  factory  representative,  or a local  authorized  service  company  to perform 
maintenance  and repairs. 

 

RATING PLATE 
 

Information  on this  plate  includes  the  model  and serial  number.   When  communicating  with  the factory  about 
a unit  or requesting  special  parts  or information,  this  information  is  required  for  proper identification.  Other 
information  on the plate  is  the BTU/hr  input  of  the burners,  gas pressure  in  inches  WC, and whether  the unit 
has orifices  for  natural  or propane gas. 
 

IMPORTANT: 

 The  appliance  must  be connected  only  to the  type of  gas identified  on the  rating  plate. 

 

GAS CONVERSION 
 

We recommend  that  the appliance  be ordered from  the factory  for the  type of  gas at the installation  site.   
When  gas  conversion  is necessary  contact  the factory  for a proper gas  conversion  kit. 

 
 

 

 
 
 

 
 
 
 

Содержание TC36-6

Страница 1: ...MODEL TC36 6 shown COUNTER SERIES MODEL TC36RB shown MODEL TCHP36SU 6 shown MODEL TC36G shown OWNERS MANUAL AND INSTALLATION INSTRUCTIONS L LISTED U C US UL Made in U S A ...

Страница 2: ...ANY OTHER APPLIANCE FOR YOUR SAFETY If you smell gas 1 Shut off gas to appliance 2 Extinguish any open flame 3 If odor continues immediately call your gas supplier Consult your local gas supplier for instructions to be followed in the event you smell gas Post these instructions in a prominent location WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAM...

Страница 3: ...ulator will void the equipment warranty and result in a potentially hazardous condition The appliance and its individual shut off valve must be disconnected from the gas supply system during any pressure testing of that system in excess of PSI The appliance must be isolated from the gas supply system by closing its individual shut off valve during any pressure testing of the gas supply piping syst...

Страница 4: ...arance for openings into the combustion chamber and adequate air supply Means must be provided for any commercial heavy duty cooking appliance to exhaust combustion wastes to the outside of the building Air movement should be checked during installation Strong exhaust fans in the hood or in the overall air conditioning system can produce a slight draft in the room which can interfere with pilot or...

Страница 5: ...ly and blow them out with compressed air to clear any dirt particles threading chips or any other foreign matter before installing a service line Those particles will clog orifices when gas pressure is applied All connections must be sealed with a joint compound for LP gas and tested with a soapy water solution before lighting any pilots FLEXIBLE COUPLINGS CONNECTORS AND CASTERS If the unit is to ...

Страница 6: ... valves and thermostats are in the off position LIGHTING THE PILOTS CAUTION When lighting the pilots and checking for leaks do not stand with your face close to the Combustion chamber OPEN TOP Remove top grates Make sure pilot adjust valve located on the manifold is open Light the pilot and adjust flame to approximately GRIDDLE Looking through slot in the valve panel locate pilot lighting holes in...

Страница 7: ...ntire griddle surface 4 Turn all griddle burners to medium or thermostats to 350 degrees and wait until the shortening begins to smoke and then turn the burners off 5 Rub the now melted shortening into the griddle surface with a cloth covering the entire surface 6 Let the griddle cool and then repeat steps 3 4 5 7 When the griddle is cool after the second seasoning wipe it once again with a thin f...

Страница 8: ...ed over about every week depending on the amount of cooking being done and the type of food being prepared GRIDDLE Scrape with a nylon griddle scraper to remove cooked on spills Use a fine grained stone only when absolutely necessary Wipe away any griddle stone dust and food particles with a cloth Wash with hot soapy water then rinse with vinegar and water solution Then rinse again with clean wate...

Страница 9: ...l not ignite 1 Pilot blocked or dirty 2 Pilot adjusting screw closed 1 Clean pilot 2 Open adjust flame length Griddle too hot or not hot enough Thermostat out of calibration Check calibration HOW TO OBTAIN SERVICE For warranty service contact your local THERMA TEK authorized service agency Provide him or her with the Model Serial date of installation and a brief description of the problem If you n...

Страница 10: ...9 HOT PLATE Counter Series ...

Страница 11: ... Manifold Pipe 60 1 81021 06 Manifold Pipe 72 1 8 80030 Manual Gas Valve 2 4 6 8 10 12 9 81018 Pilot Adjust Valve 1 2 3 4 5 6 10 81003 01 1 8 NPT Pipe Plug 1 1 3 3 3 5 11 30194 Drip Tray Slide 1 1 1 12 30193 Center Support Bracket 2 4 4 13 30200 Center Drip Shield Bracket 4 4 4 14 30199 Center Drip Shield 1 1 1 15 30195 01 12 Drip Tray 1 30195 02 24 Drip Tray 1 2 30195 03 36 Drip Tray 1 2 30195 04...

Страница 12: ...GRIDDLE Counter Series 11 ...

Страница 13: ...lug 1 1 3 3 3 5 1 0 30221 Griddle Bucket 1 1 1 1 2 2 1 1 8001 5 01 BJ Thermostat Knob Griddle 1 1 2 2 3 3 1 2 8001 4 BJ Bezel 1 1 2 2 3 3 1 3 8001 7 01 BJWA Griddle Thermostat 1 1 2 2 3 3 1 4 8001 9 TEE Thermostat 1 1 2 2 3 3 1 5 81 01 5 90 Elbow 3 8 CC x 1 4 NPT 1 1 1 1 6 81 027 TEE 3 8 CC 1 4 NPT 1 2 3 3 1 7 9001 3 3 8 x 8 Flexible Gas Tubing 1 2 3 4 5 6 1 8 81 01 4 Elbow 3 8 TOD 3 8 27 UNS 1 2 ...

Страница 14: ...BROILER Counter Series 13 ...

Страница 15: ...ray 1 2 1 30195 03 36 Drip Tray 1 1 2 30195 04 29 5 8 Drip Tray 1 30195 05 23 Drip Tray 1 11 81026 Pilot Valve TEE 3 16 1 12 81014 Elbow 3 8 TOD 3 8 27 UNS 1 2 3 4 5 6 13 81016 01 Orifice Elbow 3 8 27 x 3 8 CC 1 2 3 4 5 6 14 90013 3 8 x 8 Flexible Gas Tubing 1 1 2 2 3 3 15 81022 39 Orifice Drill 39 Nat 1 2 3 4 5 6 81022 52 Orifice Drill 52 LP 1 2 3 4 5 6 16 90038 Pilot Tip Assy 3 16 x 12 5 Lg 1 2 ...

Страница 16: ...goodworkingcondition AuthorizedService Agencymay require a credit cardbefore entering premises for non warrantedissues 8 This states the exclusive remedyagainst Therma Tekrelatingtothe product s whether in contract orin tort orunder anyother legal theory andwhether Arisingout of warranties representations instructions installations or defects from any cause 9 This warrantyandthe liabilities set fo...

Отзывы: