Therma-Stor Ultra-Aire DEH 3000R Скачать руководство пользователя страница 2

Table of Contents

1. Contents & Specifications ............................................... 2
2. Installation ...................................................................... 2

2.1 Install Instructions ...................................................... 2
2.2 Wiring......................................................................... 3
2.3 Auxiliary Relay, A/C Lockout or Run Central Fan .......... 3
2.4 Dehumidifier, Activate/De-Activate with A/C Unit ......... 4
2.5 Testing ....................................................................... 5
2.6 Troubleshooting .......................................................... 5

 3. Operation ....................................................................... 5

3.1 Display ....................................................................... 6
3.2 Setting ....................................................................... 6
3.3 Personal Settings reference ........................................ 6
3.4 On/Off and Display items ............................................ 6
3.5 Setting Clock Time ..................................................... 6
3.6 Adjusting the Relative Humidity Setpoint..................... 6
3.7 Fan Setting & Operation ............................................. 7
3.8 Damper Operation and Ventilation,  
Manual (Hold) mode ......................................................... 8
3.9 Damper Operation and Ventilation,  
Programmed Ventilation ................................................... 8

4.0 Temperature Cutout Programming ................................ 9 
5.0 DEH3000R .................................................................. 10 
Warranty ........................................................................... 11

Read and Save These Instructions

 WARNING!

 

— This symbol means important 

instructions. Failure to heed them can result in serious 
injury or death.

1. Specifications

Part # (P/N):  

4028w407

Model:  

DEH 3000R

Operating Voltage:  

24 VAC

Max Current - DMP, COMP, FAN  1 AMP each
Humidity Range/Accuracy:  

10 – 95% RH, 

±

 5%

Auxillary Relay Capacity: 

5 Amps, 24VAC

Temp Range/Accuracy:  

30°-90°F, 2%

Size:  

4.95"L x 1.06"W x 4.19"H

2. Installation

Install the DEH 3000R control panel in a central area of the 
structure where it will sense the relative humidity of the 
structure accurately. Do not install the control panel where it 
may not accurately sense the relative humidity such as near 
HVAC supply registers, near exterior doors and windows, or 
near a pool or spa. Install in accordance with all applicable 
codes and standards.

2.1 Install Instructions

1.   Separate the front panel from the back panel by depressing 

the middle sections of the top and bottom of the front 
panel.

2.   Locate the wiring access hole in the wall or other flat 

mounting surface. Place the back panel into position and 
drill the appropriate mounting holes.

3.   Insert the screws and tighten. Level as necessary.
4.   Make the electrical connections to the terminals on the 

back panel as shown in the applicable wiring diagram (see 
Sections 2.2-2.4).

5.  Test the installation (see Section 2.5).

2

DEH 3000R Dehumidifier & Ventilation System Controller

 Installation, Operation & Service Manual

Содержание Ultra-Aire DEH 3000R

Страница 1: ...ASE LEAVE MANUAL FOR HOMEOWNER Dehumidifier Ventilation System Controller 2008 Therma Stor LLC Manual P N TS 506b P O Box 8680 Madison WI 53708 TOLL FREE 1 800 533 7533 www thermastor com sales therma...

Страница 2: ...95 RH 5 Auxillary Relay Capacity 5 Amps 24VAC Temp Range Accuracy 30 90 F 2 Size 4 95 L x 1 06 W x 4 19 H 2 Installation Install the DEH 3000R control panel in a central area of the structure where it...

Страница 3: ...e optional motorized damper that can be installed into a fresh air duct This damper provides the ability to control fresh air ventilation using the ventilation timer function of the DEH 3000R and the...

Страница 4: ...C transformer that reads 0 volts between it and the Yellow air conditioning call for cooling wire The incorrect wire will give a 20 to 28 volt reading 2 Another Yellow wire must be added to the thermo...

Страница 5: ...t again to switch the fan to the ON setting c Confirm that the Ultra Aire fan is ON Ultra Aire compressor must be OFF Ventilation damper if used should be CLOSED 6 Verify optional VENT operation if el...

Страница 6: ...A flashing O before the SET POINT VENT OR FAN indicates the unit is in wait mode 3 2 Setting During the set up process if you make a mistake simply continue You can always go back to adjust the settin...

Страница 7: ...an Setting and Operation Use the FAN button to change the fan operation There are 2 choices for fan operation ON or AUTO The factory preset is AUTO ON The fan in the Ultra Aire dehumidifier will run c...

Страница 8: ...he display Release the button 2 Press the VENT button again to switch between OPEN and CLOSED 3 Leave the control alone for 10 seconds and your settings will be saved 3 9 Damper Operation and Ventilat...

Страница 9: ...schedule Repeat the steps listed above for this and the SAT SUN day and night schedules When you have finished programming your schedule either the 7 day version or the weekday weekend split version u...

Страница 10: ...splice connectors provided Avoid routing parallel to high voltage wiring Maintain a distance of 2 ft or more from high voltage lines 2 Sensor connection The sensor can be mounted to a wall or ceiling...

Страница 11: ...ome effective after initial purchase of the Product by Customer Customer Responsibilities As a further condition to obtaining warranty coverage hereunder the Customer must send a valid warranty claim...

Страница 12: ...t to change without notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Ther...

Отзывы: