10
Santa Fe ULTRAMD33 Installation & Operation Instructions
Santa-Fe-Products.com | 800.533.7533
Step 12.
If the drain access cover was removed,
reinstall it by routing the drain hose through the
appropriate knock out and reattach the screw.
Route the grommet over the drain hose and snap
into place at the knock out.
Use 1
/
4" hex nut screwdriver to apply hose
clamp to the drain hose and secure onto the
drain port hose barb.
12.
Step 14.
Tuck the electrical wires in and reinstall
electrical cover with its two screws using 1
/
4" hex
nut screwdriver. Be sure none of the electrical
wires are pinched.
Step 15.
Turn breaker / power back on.
Step 16.
Set the digital controller to desired
RH. See Controls Section on page 12.
Step 17.
Install diffuser cover by aligning
the lower tabs first, then setting the cover
back against the wall. Insert the included
four tamper resistant or phillips screws to
secure the diffuser cover.
DEHUMIDIFIER INSTALLATION
14.
17.
Step 13.
Complete electrical connections:
• white to white
• green to green
• black to black
Screw wire nuts back onto each electrical
connection.
Then tighten clamp screws on non-metallic
cable clamp.
Power Board
Non-Metallic Cable Clamp
13.
Hose
Hose Clamp
Grommet for
Drain Hose
Make sure drain hose is routed to the appropriate
location before turning on the unit.
Содержание Santa Fe UltraMD33