1 Specifications

Part No.

 

4027300

Power

 

User selectable 30/50 A operation 

 

220/240 VAC 

 

60 Hz,  Phase 

 

30 Amp = 46°F temperature rise; 8,000 BTUs 

 

50 Amp = 80°F temperature rise; 3,000 BTUs

Blower

 

360 CFM 

Filters

 

Pleated Media MERV-

Duct Options 

Intake – 2” Flex-Duct 

 

Supply – 2” Flex-Duct

Warranty

 

Five years; 

 

st year 00% of Parts and Labor

Dimensions

 

Machine  

Shipping

Width  

20.25”  

27.5” 

Height  

40”  

45.25” 

Depth  

2.4”  

25.5” 

Weight  

90 lb  

5 lb

2 Operation

2.1 Transporting

The Phoenix FireBird must always be upright when 
transported by vehicle. It may be tipped onto its handle 
and back for loading and moving by hand. The Phoenix 
FireBird features a high-impact plastic skid plate which 
protects the unit while navigating obstacles such as curbs, 
stairways, and while loading into vehicles.

2.2 Electrical Requirements

The Phoenix FireBird requires 220/240VAC.  The FireBird 
outlet is 240VAC with ground.  When properly installed, 
it provides a ground connection through the cord to the 
heater to protect the operator from electric shock.  The 
Phoenix FireBird comes equipped with two 8’ long cords 
for connection to grounded residential range and dryer 
receptacles.  An accessory extension cord is also available 
(see Accessories).

2.3 Ducting

The Phoenix FireBird can be ducted at the inlet, the 
outlet or both using the included round outlet adapter.  
The FireBird lid and outlet adapter are designed to 
accommodate 2” flexible duct.  When selecting flexible 
ducting keep in mind anticipated outlet temperatures.  Air 
temperature increase is typically 50 to 80 degrees F for 
low and high power settings respectively.  Adding ducting 
decreases airflow which can increase outlet temperatures 
by up to 20 additional degrees F. 

Install the 2” duct adapter by lining up the notch of the 
adapter with the rivet on the cabinet, then push in the 
directions shown to engage fasteners.

2.4 Power Switch

Master POWER Switch: 

The master power switch located 

on the back of the FireBird can be used to turn the unit 
ON, OFF, or set the unit to be controlled by an external 
thermostat.
When set to ON, the FireBird will energize the blower 
relay and heater elements(s) continuously.  In this mode, 
the heaters are thermostatically limited to 40 degree F 
incoming air temperature with an automatic switch.
When set to THERMOSTAT, the blower and heater will run 
when the thermostat terminals (located under the lid) are 
connected by a switch, remote thermostat, timer, etc.

HIGH/LOW POWER Switch: 

This switch selects either 

high or low power operation.  If this switch is set to HIGH 
POWER operation, the FireBird MUST be connected to a 
minimum 50 Amp source.

2.5 Hour Meter

The digital hour meter measures the cumulative time that 
the unit is turned on to tenths of an hour. It stores and 
displays the total when the unit is unplugged. It resets to 
zero after 99,999.9 hours of operation.

2.6 Remote Thermostat Connection

To connect a remote thermostat, switch, or timer control, 
first locate the thermostat terminals under the lid of 
the FireBird.  There are 2 spring loaded terminals for 
connecting thermostat wiring.  Any dry-contact switch, 
thermostat, or other type of control that connects the 
terminals together will cause the heater to run.  The 
thermostat circuit is low voltage (24VAC).  DO NOT 
CONNECT POWER TO THE THERMOSTAT TERMINALS.
Always press terminal levers to release spring pressure 
before disconnecting thermostat wiring.  Failure to do 
so will lead to excessive wear on spring loaded terminal 
connector.

SLIDE DOWN 
INTO PLACE

PUSH IN

Содержание Phoenix FireBird

Страница 1: ...ing the 30 amp setting the FireBird produces 18 000 BTU s giving a 46 F temperature rise Internal temperature cutouts prevent the FireBird from overheating an area while the FireBird s externally loca...

Страница 2: ...er Return to authorized service facility for adjustment or repair Device not intended for use directly in an area where it may fall into a bathtub or other water container DO NOT run cord under carpet...

Страница 3: ...ecreases airflow which can increase outlet temperatures by up to 20 additional degrees F Install the 12 duct adapter by lining up the notch of the adapter with the rivet on the cabinet then push in th...

Страница 4: ...nts together provide high power operation The heating elements and the blower are operated by a 24VAC control circuit and a number of relays and contactors For safety there is an air pressure switch t...

Страница 5: ...Blue 50 AMP Receptacle Blue Black Red Black Black 3800 Watt 14 Contactor 2 L1 Blue Blower Black 230 V 24 V Optional Thermostat Master Power Switch Pressure Switch 140 Thermal Cut Out Hi Low Power Swit...

Страница 6: ...ermal Switch 1 4026898 5 Pressure Switch 1 4027305 6 Blower Relay 1 4022484 7 5mf Capacitor 1 4027315 8 Heating Element 1 4027317 9 Flanged 50A Inlet 1 4027308 10 Master Power Switch 1 4027310 11 Hour...

Страница 7: ...reasonable control Limitation and Exclusions If any Phoenix FireBird part is repaired or replaced the new part shall be warranted for only the remainder of the original warranty period applicable the...

Отзывы: