background image

2

www.UsePhoenix.com • [email protected]

Toll-Free 1-800-533-7533

1 Safety Precautions

•  Unit Intended for INDOOR USE ONLY; DO NOT USE 

OUTDOORS.

•  Device is HOT when in use. To prevent burns, avoid skin 

contact with hot surfaces.

•  Use handle when moving device.

Read the operation and maintenance instructions carefully 
before using this unit.
Proper adherence to these instructions is essential to  
obtain maximum benefit from your Phoenix D850 
dehumidifier. 

Table of Contents

Introduction

 .................................................................................1 

1.   Safety Precautions

 ..............................................................2

2.   Specifications

 ......................................................................2

3.   Operation

 .............................................................................3

 

3.1 How the Phoenix D850 Works ......................................3

 

3.2 Avoiding Secondary Damages ......................................3

 

 3.3 Transporting ..................................................................4

 

3.4 Electrical Requirements ................................................4

 

3.5 Location .........................................................................4

 

3.6 Ducting Connections .....................................................4

 

3.7  Ducting Options.............................................................5

 

3.8 Control Panel .................................................................5

 

  

 

3.8.1 POWER SETTING Switch .....................................5

 

    3.8.2 CONTROL MODE Switch .....................................5

 

    3.8.3 BALANCE Knob ....................................................6

 

    3.8.4 Indicator Lamps ..................................................6

 

    3.8.5 TOTAL RUN TIME Meter .......................................6

 

    3.8.6 Low-Voltage EXTERNAL CONTROL Connection .6

4.   Maintenance

 ........................................................................6

 

4.1 Air Filter Replacement ...................................................6

 

4.2 Blower Motors and Rotor Drive Motor ..........................6

 

4.3 Desiccant Rotor Cassette Assembly ............................6

 

    4.3.1 Seals ....................................................................7

 

    4.3.2 Desiccant Rotor ...................................................7

5.   Service

 ..................................................................................7

 

5.1 Technical Description ....................................................7

 

5.2 Normal Operation ..........................................................7

 

5.3 Troubleshooting .............................................................8

6.   Wiring Diagram

 ...................................................................9

7.  Service Parts List

 ...............................................................10

 

Warranty .............................................................................11

Serial No. ___________________________

Purchase Date ______/______/_____

Dealer’s Name ___________________________________

•  Maintain 36” minimum clearance between device outlet 

and any combustible materials such as furniture, pillows, 

bedding, papers, clothes and curtains.  Keep such items 

away from sides and rear of device.

•  Extreme caution is necessary when device is used by 

or near children and whenever device is left operating 

unattended.

•  Always unplug unit when not in use.
•  DO NOT OPERATE with damaged cord, plug, or after 

unit malfunctions, has been dropped or damaged in 

any manner. Return to authorized service facility for 

adjustment or repair.

•  Device not intended for use directly in an area where it 

may fall into a bathtub or other water container.

•  DO NOT run cord under carpeting or other floor covering. 

Arrange cord away from traffic area and where it will not 

be tripped over.

•  To disconnect device, turn controls off, then remove plug 

from outlet.

•  Connect ONLY to properly grounded outlets.
•  DO NOT insert or allow foreign objects to enter any 

ventilation or exhaust openings as this may cause an 

ELECTRIC SHOCK or FIRE, or damage the heater.

•  To prevent a possible fire, do not block air intakes or 

exhaust in any manner. Do not use on soft surfaces, like 

a bed, where openings may become blocked.

•  Device has hot and arcing or sparking parts inside. Do 

not use in areas where gasoline, paint, or flammable 

liquids are used or stored.

•  Use device only as described in this manual. Any other 

use not recommended by the manufacturer may cause 

fire, electric shock, or injury to persons.

•  Avoid use of an extension cord because the extension 

cord may overheat and cause a risk of fire. However, 

if you have to use an extension cord, the cord shall be 

No. 6 AWG minimum size and rated not less than 9600 

Watts.

2 Specifications

Part No.

 4034000

Power

 

208-240VAC, 50/60Hz, Single Phase 

 

30A or 50A branch circuit protection  

 

(24A or 40A actual amp draw)

Water 

370 pints per day at 80°F, 60%RH 

Removal

Blower

 

850 CFM Process Airflow 

 

225 CFM Reactivation Airflow

Operating  

-10°F to 120°F  

Range

   

Filters

 

Process filter size: 20” x 20” x 2”

 

Reactivation filter size: 9” x 11 3/8” x 1/4”

 

Содержание Phoenix D850

Страница 1: ...e most crawlspaces The lower carrying handle makes moving the unit into and out of the crawlspace a breeze Having the D850 securely inside the crawlspace deters the possibility of tampering with the d...

Страница 2: ...e is used by or near children and whenever device is left operating unattended Always unplug unit when not in use DO NOT OPERATE with damaged cord plug or after unit malfunctions has been dropped or d...

Страница 3: ...rain hose or condensate pump Note Check for airflow at all inlets and outlets DO NOT run unit if no airflow is detected Process Air Stream Fig 1 P1 850 CFM of air enters 18 or 12 flex the machine and...

Страница 4: ...t is designed to be used INDOORS ONLY If used on a water loss work site plug it into GROUND FAULT CIRCUIT INTERRUPT GFCI OUTLETS Maintain a minimum of 36 clearance around the D850 DO NOT use the Phoen...

Страница 5: ...To attach the collar to the D850 align the three tabs with their slots in the cabinet and the small round hole with the snap button then push the collar into the unit and twist it counter clockwise u...

Страница 6: ...rly Process air stream filter This 20 x 20 x 2 filter is located in the top of your D850 inside the upper access door Depress the snap buttons on the sides to open the access door The included filter...

Страница 7: ...esiccant rotor by means of a sprocket which bears directly on the rotor circumference Heat for reactivation is generated by a two stage wound nichrome heating element providing two heat settings depen...

Страница 8: ...ide device 4 Defective blower or blower capacitor 5 Relay not operating Regen blower and rotor motor running Process blower not running 1 Fault condition on VFD Power unit off for 30 seconds and resta...

Страница 9: ...3960W HEATER BLOWER ROTOR MOTOR RELAY 12A BREAKER BEHIND PANEL 8640W LAMP HI LOW POWER SETTING SWITCH WIRING BLOCK 2 PIN MATE N LOK 9 PIN MATE N LOK 9 PIN MATE N LOK ROTOR MOTOR PROC BLWR 230VAC 3PH...

Страница 10: ...ANT WHEEL 1 16 4036124 SEAL KIT DESICCANT WHEEL 1 17 4034878 INDICATOR LAMP 3 Item Part No Description Qty 18 4036842 PRESSURE SWITCH 1 19 4036118 THERMAL OVERLOAD PROCESS INLET 1 20 4022636 AIR FILTE...

Страница 11: ...tallation accident acts of nature or any other cause beyond Therma Stor LLC reasonable control Limitations and Exclusions If any Phoenix D850 Dehumidifier part is repaired or replaced the new part sha...

Отзывы: