background image

8

www.UsePhoenix.com  •  [email protected]

Toll-Free 1-800-533-7533

Figure 4

Specifications subject to change without notice.

6 Service Parts

Item 

Description 

Qty 

Part No.

Top Cover 

4028583

Top Cover Hinge 

4027267

Wheel 12” Gray 

4026304

Cotter Pin 3/32” 

1284404

Air Filter 1.75 x 15.5 x 19.5 

4021475

Hose Plastic 0.62 ID x 28 

4025708

Hose Plastic 0.38 ID 

4021909

Hose Plastic 0.25ID x 33 

4024916

Coupling Body 0.25 Tube 

4024910

10 

Coupling Insert 0.38 Tube 

4023080

11 

Control Board 

4028579

12 

Capacitor Compressor

 

55mfd 370V

 

4029606

13 

Capacitor Impeller 

15mfd 371V

 

4025224

14 

Thermistor Coil 

4027278

15 

Thermistor Bulkhead 

4028581

16 

Battery AA 

8523901

17 

Cord 115V 25’ 

4025078

18 

Compressor 

10.2KBTU R410a

  1 

4029176

19 

Overload Compressor 

4029177

20 

Evaporator Coil 

4028565

Item 

Description 

Qty 

Part No.

21 

Condenser Coil 

4028566

22 

Condensate Pump 

4023649

23 

Fan Motorized Impeller 

4026657

24 

Inlet Ring 

4028564

25 

Wire Duct Collar 

4028593

26 

Relay SPST 100/120V 25A 

1970010

27 

Filter Drier (not shown) 

4029510

28 

Actuator 12VDC 

4028587

29 

Adaptor Actuator 

4028575

30 

Wire Harness (not shown) 

4028580

31 

Handle 

4026094

32 

Bolt M10-1.5 X 35 

1177792

33 

Washer M10 X 30 

4025517

34 

Hex Lock Nut M10-1.5 

1223780

1, 5, 8

7, 9, 10

3, 4

21

20

17

2

26

25

23, 24

18, 19

14

15

6

22

11, 16,

28, 29

31, 32
33, 34

12

13

Содержание Phoenix 270HTx

Страница 1: ...12 intake 10 exhaust Solid State Controls Easy to read and operate Recessed 12 Wheels Allows greater maneuverability on the job site and efficient storage Rolls over obstacles with ease MERV 11 Pleat...

Страница 2: ...walls and other obstructions to air flow Table of Contents Introduction 1 1 Specifications 2 2 Operation 2 2 1 Transporting the Phoenix 270HTx 2 2 2 Location 2 2 3 Electrical Requirements 3 2 4 Conden...

Страница 3: ...oir before transport or storage Turn off the power and allow the plugged in dehumidifier to rest 15 minutes before the final purge 2 8 Hour Meter The digital hour meter displays the cumulative and job...

Страница 4: ...d If the unit will not be exposed to freezing temperatures an alternative to reduce biological growth is to flush the unit with a bio fungicide that is approved for use with copper aluminum and polyet...

Страница 5: ...cuit 2 Obstruction prevents impeller rotation 3 Defective air mover 4 Defective control board Unit removes some water but not as much as expected 1 Air temperature and or humidity have dropped 2 Humid...

Страница 6: ...ng the pump bracket to the base 5 Replace the pump hose wiring bolts and cover in the reverse order 4 6 Refrigerant Charging If the refrigerant charge is lost due to service or a leak a new charge mus...

Страница 7: ...7 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 5 Wiring Diagram 4028595...

Страница 8: ...peller 15mfd 371V 1 4025224 14 Thermistor Coil 1 4027278 15 Thermistor Bulkhead 1 4028581 16 Battery AA 4 8523901 17 Cord 115V 25 1 4025078 18 Compressor 10 2KBTU R410a 1 4029176 19 Overload Compresso...

Страница 9: ...9 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 This page intentionally left blank...

Страница 10: ...anty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts o...

Отзывы: