The thermostat has a keypad lock facility. To activate the lock follow these steps.

•  Use the Left / Right keys to scroll to HOLD & press Tick for 10 seconds. 
•  The display will show 00:00 and you will need to enter a four digit pin number.
•  Use the Up / Down keys to enter the first two digits ...............................
•  Press Tick to confirm ............................................................................
•  Use the Up / Down keys to enter the second two digits .........................
•  Press Tick to confirm ...........................................................................

The display will return to the main screen and display the keypad lock indicator.
Note: The keypad lock indicator is only displayed when the lock is active.

To unlock the therM stat press Tick once. The display will show 00:00 and you will 
need to enter the four digit pin number you set previously.

•  Use the Up / Down and Tick keys to enter the first two digits .................
•  Use the Up / Down and Tick keys to enter the second two digits ...........

The display will unlock and return to the main screen.

Use the Left / Right keys to scroll to the Power Icon ...............................
The frost icon will toggle ON/OFF each time Tick is pressed ..................................

In this mode, the therM stat will display the frost icon and will only turn 
the heating ON should the room temperature drop below the set frost temperature 
(see page 23). If the heating is turned ON whilst in frost mode, the flame symbol 
will be displayed.            

To cancel the frost protect mode, navigate to the Power button again and 
press Tick ............................................................................................................

Frost Protection Mode Enabled

Locking the therM stat

Unlocking the therM stat

Frost Mode

Содержание Stat

Страница 1: ...1...

Страница 2: ...ing Times Timer Override Optional Features Optional Features Table Time Clock Mode Wiring Diagram Mode 2 Time Clock LCD Display Temperature Display Setting the Clock Setting the Comfort Levels Setting...

Страница 3: ...room cools down Setting a programmable room thermostat to a lower temperature will result in the room being controlled at a lower temperature and saves energy The way to set and use your programmable...

Страница 4: ...rams on pages 28 31 of this booklet Note For time clock wiring connections terminate as shown on page 38 Step 3 Screw the thermostat back plate securely into the back box Step 4 Clip the front of the...

Страница 5: ...two minutes to join the therM stat to the therM hub On the therM stat use the Left Right keys to select SETUP and press Tick Feature 01 is displayed on screen Press the Tick key to pair the therM sta...

Страница 6: ...oling control feature option Cooling mode must be initially enabled within the thermostat feature menu Cooling can only be activated from the therM app or therM chill When in cooling mode the therM st...

Страница 7: ...urrent sensor mode 8 Set Displayed when changes are being made to the program schedule or current set point 9 Key Lock Indicator Displayed when the KeyLock is Locked 10 Program Indicator Displayed dur...

Страница 8: ...rrent floor temperature press and hold the Left and Right arrow keys for 5 seconds the floor temperature will then be displayed To set the clock follow these steps Use the Left Right keys to scroll to...

Страница 9: ...g each day of the week can have four different comfort levels In 24 Hour mode all days are programmed with the same comfort levels To program the comfort levels use the Left Right keys to scroll to ED...

Страница 10: ...selection Use the Up Down keys to set the desired Hold period Press Tick to confirm selection Use the Up Down keys to set the desired Hold temperature Press Tick to confirm selection You will see the...

Страница 11: ...show 00 00 and you will need to enter the four digit pin number you set previously Use the Up Down and Tick keys to enter the first two digits Use the Up Down and Tick keys to enter the second two di...

Страница 12: ...see page 23 In time clock mode the holiday function maintains the timed output as OFF The thermostat will maintain this temperature for the duration of the holiday and will then automatically return...

Страница 13: ...ture 07 Floor Temp Limit This function is available when mode 07 is set to 03 or 04 You can set a floor limiting temperature between 20 45 C 28 C is the default setting Note Air Sensor only MUST NOT b...

Страница 14: ...l Set Temperature Program Mode Temperature Format DESCRIPTION Used to add zone to the therM hub 00 0 5o C 01 1 0o C Default 02 2 0o C 03 3 0o C 07o 17o C 12o C Default 00 15 Minutes 00 Default 00o 10o...

Страница 15: ...ed a fault E1 The remote FLOOR probe has not been connected The remote FLOOR probe has not been wired correctly The remote FLOOR probe is faulty E2 The remote AIR probe has not been connected The remo...

Страница 16: ...LR LS LR ARE NORMALLY THE ROOM THERMOSTAT CONNECTIONS TO BOILER HEATING VALVE NEUTRAL NEUTRAL LIVE 230V SUPPLY IN A1 A2 L N 230VAC RT1 RT2 This product must only be installed by a qualified electricia...

Страница 17: ...e Clock Press the Tick key to confirm selection The thermostat will revert to the main display screen for the selected mode Note Factory reset will cancel all parameters that were entered during the s...

Страница 18: ...or current set point 5 Program Indicator Displayed during programming to show which period is being altered 6 Main Menu Displays which option is currently selected 7 Timer Status Displays the current...

Страница 19: ...e the Up Down keys to select the OFF time HOURS and press Tick Use the Up Down keys to select the OFF time MINUTES Press Tick to confirm selection Press the Right arrow key 2 will now flash and the cu...

Страница 20: ...lows you to program 4 on off switching times for the weekdays and 4 on off switching times for the weekend 7 Day Program Mode Each day has 4 on off switching times that can be programmed independently...

Страница 21: ...to help call us now on 0845 890 5685 www thermcontrols com technical thermcontrols com info thermcontrols com therM is a registered Trademark of Plumb Partners Group Ltd All rights reserved Specificat...

Отзывы: