![THERM-OZ RENO KIT Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/therm-oz/reno-kit/reno-kit_instructions-manual_1101874013.webp)
COMMISSIONING
PLEASE NOTE. THE THERMOSTATIC CARTRIDGE HAS BEEN CALIBRATED AT THE
FACTORY AND SET AT 38°C AT 300 kPa . IF FOR WHAT EVER REASON THIS NEEDS
TO BE RE
-
SET, PLEASE FOLLOW THESE INSTRUCTIONS.
YOU WILL NEED A THERMOMETER
Remove the shower hose from the
bottom outlet of the thermostatic valve.
With the Left handle positioned on the
38°C mark, turn the right handle to start
flow and place thermometer into the
running water.
If the temperature is less or more than
38°C turn off the flow then do as follows:
Remove Right handle, to expose Locating Ring (fig 1)
38
2.
LOCATING
RING
Note how the ridge of the locating ring is in line with
the number 38. (fig 2)
Pull the locating ring off, but remember it will need to
be replaced later, in the same position, with the ridge
in line with the number 38.
Turn on the right handle to start the flow, and place
the thermometer into the running water.
To obtain 38°C gradually rotate the spline in the
direction it needs to be, to increase or decrease the
temperature with your fingers (fig 4)
Once you have a delivered temperature of 38°C, turn
off the flow and replace the locating ring as per fig 2.
Replace handle with the safety over ride button in
line with the number 38. Replace shower hose to the
outlet.
3.
SPLINE
1.
4.
THE THERMOSTATIC MIXING VALVE IS NOW FULLY COMMISSIONED
AND CALIBRATED TO 38°C .
PLEASE CONTACT US IF YOU HAVE ANY PROBLEMS
Page 12
Содержание RENO KIT
Страница 18: ......