Page | 

25

 

                   

 

The device should be stored and cleaned according to the recommended 
conditions describe in the user manual 

 

6.4. REVIEWING YOUR MIGRAINE DIARY 

Keeping  detailed  records  of  migraine  episodes  can  help  in  migraine  management.  The 
symptoms  recorded  during  a  treatment  will  be  saved  in  a  migraine  diary  that  can  be 
reviewed at any time via the app. T

ouch “Diary” to review your migraine symptoms.  

You can also report a current migraine headache and records your symptoms in the diary 
even if the device is not used.  

To  help  you  track  your  migraine  headaches,  the  app  will  provide  notification  to  fill  your 
symptoms  at  2  hours and  at  24  hours  after a  treatment  session or  a  reported  migraine 
headache. You can disable these notifications in the smartphone settings.   

The  migraine  diary  can  also  be  accessed  via  the  web.  Type 

https://diary.nerivio.com

 

in 

your web browser and enter your account details. To view your login details in the app, 
touch 

“More” and then touch “View profile”.  

 

 

7. CLEANING, MAINTENANCE AND DISPOSAL 

 

7.1. CLEANING AND MAINTENANCE 

 

  The device can be cleaned with a dry cloth (except for the electrodes). 

  If the electrodes begin losing adhesion, gently rubbing one or two drops of water 

onto the gel surface may extend usage. 

  The armband can be washed with water and soap only. No bleach products should 

be used. Do not tumble dry. Do not iron.  

  To minimize moisture loss, when unused, the electrodes should be covered  with 

the provided protective film and the device should be stored in its original package.

 

  Contact customer support if the package and/or device labeling are damaged. 

  The lifetime of the electrodes varies depending on skin conditions, skin preparation, 

storage and climate. 

  The  app  can  be  updated  using  the  standard  update  procedure  of  the  mobile 

operating system  
 
 

 

Before or after a treatment, rub the electrodes using a drop of water to improve 
their adhesiveness  

 

Do not clean the device with soap, alcohol, submerge in water, or scrub with 
abrasive material 

Содержание Nerivio

Страница 1: ...Nerivio A wireless non invasive neuromodulation device for the acute treatment of migraine USER MANUAL...

Страница 2: ...ced without the written permission of Theranica Theranica reserves the right to change or improve its products and accompanying technical literature without specific notice Manufacturer Theranica Bio...

Страница 3: ...ce 25 7 2 Disposal 26 8 Troubleshooting 26 8 1 General 26 8 2 Main errors and messages 27 8 3 LED status 28 8 4 Customer support 28 9 Operation specification 29 9 1 Environment operating conditions 29...

Страница 4: ...roduces electrical signals The device is good for 12 treatments of 45 minutes 2 Armband and an extension The armband should be wrapped around the device on the arm to improve the contact between the d...

Страница 5: ...tion on the arm and to conceal the device to enable a discreet treatment An extension is also provided for larger arm sizes An application app installed on a smartphone to control and monitor the trea...

Страница 6: ...mpliance with FCC Federal Communications Commission Class B certified for home use FCC identifier 2AOH8 NM Manufacturer Type BF applied part IEC60601 1 Catalog number Serial number IP22 Ingress protec...

Страница 7: ...t WEEE Directive This product must not be disposed of via municipal waste collection Separate collection for electrical and electronic equipment waste per Directive 2012 19 EC in the European Union is...

Страница 8: ...could cause electric shock electrical interference or serious injuries or medical conditions 4 2 WARNINGS PRECAUTIONS AND ADVERSE EVENTS The following icons are used throughout this user manual Warni...

Страница 9: ...to cancerous lesions Do not use the device on an arm with a metallic implant In such cases consider using it on the other upper arm Do not use the device simultaneously with another electrical stimul...

Страница 10: ...ty may occur in the vicinity of equipment emitting RF e g microwave routers Wi Fi devices To minimize moisture loss when unused the electrodes should be covered with the provided protective film and t...

Страница 11: ...ng numbness in the arm pain in the arm or redness of the skin which should disappear shortly after the end of the treatment Refer to Theranica s website at https theranica com for a complete listing o...

Страница 12: ...hone requirements Step 2 Download and install the Nerivio app via Google play or App store depending on your operating system Step 3 You will be asked to create an account Follow the app instructions...

Страница 13: ...at least 1 uppercase letter at least 1 lowercase letter and at least 1 numeric digit During the sign up process the app will send you a verification email to the email address which you have registere...

Страница 14: ...o device to the app using the app instructions The device and the smartphone should be in proximity of less than 1 inch 2 5 cm As you begin using the app it may ask for permissions Please allow these...

Страница 15: ...e it for next use or start a treatment following the instructions below If the device was on for over 10 minutes when no treatment was initiated it automatically shuts down Turn it back on to start a...

Страница 16: ...s and migraine headaches More screen This screen provides access to some of the technical aspects of the app View profile Select this to view your account details Buy Nerivio Select this to but a Neri...

Страница 17: ...lect to enter a code if applicable Sign out select this to sign out of your account 6 2 TREATING A MIGRAINE HEADACHE The treatment should be performed at the onset of a migraine headache For effective...

Страница 18: ...slow flashing mostly on green light indicates the device is on If the LED is still off or is solid green please contact customer support Step 4 Open the app and confirm the device is connected succes...

Страница 19: ...device should be located midway between the elbow and the shoulder Place the device directly on the skin and not on your shirt Step 7 Adjust the armband to your size There are 4 sizes you can choose...

Страница 20: ...s now begun and will stop automatically after 45 minutes A slow flashing mostly off green light indicates the device is stimulating Do not start a treatment before placing the device on your arm Do no...

Страница 21: ...tarts at a default intensity of 12 Gradually increase the intensity as described below Setting intensity level a Start increasing the stimulation intensity using the button Each press will increase th...

Страница 22: ...ntact customer support For your safety the intensity will increase slowly This gradual increase will be presented in the app by a flashing increasing indication that will stop once the desired intensi...

Страница 23: ...adual increase will be presented in the app by a flashing increasing indication that will stop once the desired intensity is reached The treatment can be stopped early at any time by touching the paus...

Страница 24: ...has ended the green light will turn off Step 2 Apply the protective film on the electrodes the protective film is reusable Step 3 Place the device in its original package or in the travel bag to store...

Страница 25: ...unt details To view your login details in the app touch More and then touch View profile 7 CLEANING MAINTENANCE AND DISPOSAL 7 1 CLEANING AND MAINTENANCE The device can be cleaned with a dry cloth exc...

Страница 26: ...ease check and confirm the following 1 Make sure that Bluetooth connection is enabled in your phone 2 Make sure that there are treatments left in your device 8 1 GENERAL Problem What it may mean What...

Страница 27: ...e phone Enable the Bluetooth feature on your phone and try to reconnect The phone and the device are not close enough Bring the phone closer to the device to a range of 1 inch 2 5 cm The device was au...

Страница 28: ...ice is turned off Turn on the device The device is too far from the smartphone Bring the phone closer to the device to a range of inch 2 5 cm Authentication failed The device has already been associat...

Страница 29: ...DITIONS Operating temperature range 5 to 40 C 41 F 104 F Relative humidity range 35 65 Atmospheric pressure 70 106 kPa 9 2 ENVIRONMENTAL STORAGE AND TRANSPORTATION CONDITIONS BETWEEN USES Temperature...

Страница 30: ...charge or detach the battery Recycle or dispose the device in accordance with disposal instructions in the user manual 10 TECHNICAL SPECIFICATIONS Number of channels 1 Waveform Biphasic rectangular mo...

Страница 31: ...play Device LED Via the mobile application if connected On off status Yes Yes Wireless connection Yes Yes Low battery No Yes remaining number of treatments Current level No Yes stimulation intensity O...

Страница 32: ...further control However the app may not enable you to stop the treatment or adjust the intensity which may result in an uncomfortable feeling If such sensation occurs please remove the device from yo...

Страница 33: ...h it is used Do not use devices which generate strong electrical or electromagnetic fields in proximity to the Nerivio device This may result in incorrect operation of the device and create a potentia...

Страница 34: ...ormatted based on IEC60601 1 2 2007 Electromagnetic emissions IEC 60601 1 2 Emissions Test Compliance Electromagnetic Environment Guidance RF emissions CISPR 11 Group 1 The Nerivio uses RF energy only...

Страница 35: ...Not Applicable 70 UT for 25 cycles Not Applicable 0 UT for 5 s Not Applicable Power frequency 50 60 Hz magnetic field IEC 61000 4 8 30 A m 30 A m Note UT is the A C mains voltage prior to application...

Страница 36: ...oadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field...

Страница 37: ...mful interference to radio communications However there is no guarantee that interference will not occur in a installation If this equipment causes interference with other devices which may be determi...

Страница 38: ...safety and essential performance IEC EN 60601 1 2 edition 4 0 Medical electrical equipment Part 1 2 General requirements for safety collateral standard Electromagnetic compatibility Requirements and t...

Страница 39: ...ca Bio Electronics LTD 4 Ha Omanut St Netanya 4250438 Israel Tel 972 72 3909 763 Fax 972 72 3909762 2018 Theranica Bio Electronics LTD All Rights Reserved www theranica com ART No LBL NM 0014 1 1 Rev...

Отзывы: