MECHANICAL AND HYDRAULIC INSTALLATION
During installation ensure that the mains cable is disconnected from the power
supply.
Acids are very corrosive and can harm your eyes, skin and airways.
When working with pH correctors necessary caution and preventive measures
should be taken. Always wear PPE e.g. safety googles, gloves and clothing.
Acid container
.
We strongly recommend to place the acid container outside the filter shed. If it is
not possible, ensure an adequate ventilation is provided and place the container
as far from metallic and electronic equipment as possible and NEVER underneath
the pump or other device.
Wireless Pump
.
Install the pump on the wall in an easy to access location using the bracket pro-
vided. Before attaching the bracket to the pump, use the bracket to mark on the
wall the location of the holes you will need to make for the screws. Choose a loca-
tion close to the injection point. The pump can be installed at any distance from
the chlorinator.
Injection
.
The injector should be installed in a HORIZONTAL position, install the clamp sad-
dle provided in the return pipe after all other equipment (pump, filter, heater, chlo-
rinator, etc.). It should be the last element on the return line. Install the injection
one way valve on the clamp saddle. Use Teflon tape to seal the thread. Connect
the injection rigid tubbing (opaque) to the valve.
Connect the other end of the injection tube (opaque) to the injection fitting [2]
(right side) of the peristaltic pump.
Suction
.
Connect the flexible suction tube (transparent) to the injection fitting [1] (left side)
of the peristaltic pump.
Use a length of tube long enough to reach from the acid container to the peristal-
tic pump and feed the tube through the black rubber grommet in the ‘anti-fume’
cap. Once the cap is on the tube, fit the suction filter to the suction tube and place
the suction line into the acid container. Screw the anti fume cap down into posi-
tion.
Ph Sensor Probe
.
Ph Sensor Probe must be installed after the media filter but before the Salt cell
with a 300mm distance from the cell to prevent damage.
Must be installed vertical with the probe pushed all the way down so the probe tip
is within the water flow.