Страница 1: ...pH Wireless Ver 21 7 1 Therachlor pH Wireless Pump...
Страница 2: ...uitable for the pool zone Ensure that equipotential bonding of all parts of the pool installation is carried out During the installation phase check the following The voltage of the power supply must...
Страница 3: ...acid into the pool when needed The wireless link allows you to install the pump and the acid container at a certain distance from the chlorinator and thus to protect the chlorinator or other equipmen...
Страница 4: ...ection The injector should be installed in a HORIZONTAL position install the clamp sad dle provided in the return pipe after all other equipment pump filter heater chlo rinator etc It should be the la...
Страница 5: ...robe 2 Probe Tightener 3 O Ring 4 Push Nut 5 Flat Gasket 6 Probe Housing 1 2 3 4 5 6 Installation of the probe Acid injection Acid injection must be installed at the last point of return to pool Must...
Страница 6: ...eless Ver 21 7 6 Heat Pump Quantum AOP Chlorination Cell Pool Pump Pool Filter pH Probe Acid Injection CAUTION Acid injector must be installed in a horizontal position to prevent the occurrence of blo...
Страница 7: ...pH Wireless Ver 21 7 7 INSTALLATION NOTES...
Страница 8: ...e pH function in the chlorinator the Wireless pump will start receiving dosing data from the chlorinator and the blue indicator will blink every second When the pH function is activated the chlorinato...
Страница 9: ...rrows to select ON or OFF Then press OK to confirm or MENU to exit 2 Setpoints pH Configuration 2 Setpoints pH 7 0 10 pH 9 0 90 The calculation of the dosage is made by establishing two setpoints and...
Страница 10: ...may need to correct the setpoints several times 3 pH probe Calibration pH Configuration 2 Cal pH 4 pH Configuration 3 Cal pH 7 pH probes require a calibration before their first use and then they nee...
Страница 11: ...units from the theoretical of the buffer solution pH4 and pH7 data calibration won t be saved and it will go back to factory values For example if the reading value is 6 05 while calibrating with pH4...
Страница 12: ...unication channel will change at the chlorinator and at the pump The blue pilot of the pump will flash again indicating that it is receiving data from the chlorinator 6 Radio channel pH Configuration...
Страница 13: ...tubes fitted in dosing pumps Squeeze tubes should be replaced every six months by a suitably qualified technician Theralux Advanced Mineral Pool Systems is not liable for any failure of its products...