INSTALLATION

 

Master Controller & Expansion Unit/s Installation 

 

Find a suitable location to mount the control box. 

Ideally, as with all pool 

equipment, it should be installed out of direct weather

 and no closer than 3 

metres from the water’s edge, at a minimum 600mm above ground. The power 

cable is 1.8m long and should be plugged directly into a general power outlet, 

not into an extension lead. 

 

Fix the mounting bracket to a solid structure via screws and wall plugs kit 
provided, and slide the controller on, locking into place.  

 

To remove unit, lift and gently pull away from mounting bracket. 

Do Not turn the power on to the Master Controller or the Expansion Units until all the 

following criteria has been met. 

 

Install Pool sensor as per instructions on page 3 of the manual. 

 

Install Roof sensor (if option chosen) as per instructions on page 3 of the 

manual. 

 

If required, fit and install any Valves Actuators that are required to run the 
system. Plug the cable from the Valve Actuator/s into the Valve sockets located 

beneath the Master Controller (see diagram located on p4 of the manual for 

location). Up to 4 Valve Actuators can be installed and controlled. 

 

If a Gas Heater or Heat Pump is installed, then connect either the Heater 

Interlock cable or the Pump Call cable as per the instructions under HEATER 

CONTROL on p2 of the main instruction booklet. 

REMEMBER: 

If the

 

heater’s flow or pressure switch circuit is 240Vac, an external relay 

can be purchased separately and is to be 

installed (KIT09) by a licensed electrician. 

 

Plug the communication cable from Expansion Unit 1 (if optioned) beneath the 

Master Controller. (see diagram on page 4] 

 

Plug the communication cable from Expansion Unit 2 (if fitted) beneath the 

Expansion Unit 1. (see diagram on p4) 

 

Plug in the Filtration Pump. If you have a variable speed pump, go to the next 
page to see the required wiring diagram for the brand/series of pump to be 

used. 

If the pump installed is a Reltech or Insnrg, a motor cable will need to be purchased 

separately. 

If the filtration pump is a single speed pump, plug directly into one of the 

power sockets located on either the Master Controller or on an Expansion Unit. 

The pump may be plugged into the Sanitiser outlet and the Sanitiser plugged 

into the controller power outlet. 

 

 

Plug all other appliance power cables that will be controlled by the POOL+ 

MANAGER into the power points located beneath the Controllers and ensure 

maximum current loads are not exceeded. 

 
 

Отзывы: