5.5 Electrical Specification
5.5.1 Power Supply
The power supply requirements are listed in the table below and are identical to the Qseven specification.
Rail
Description
Nominal voltage
Tolerance
VCC
Main power supply
5V
4.75 ... 5.25V
VCC_RTC
Backup battery
3V
2.4 ... 3.3V