3-7

Themis Computer

BIOS Setup Utility

Advanced Setup Configurations

before a power loss. The options are Power-On, Power-Off and 

Last State

.

3.3.1.11 Interrupt 19 Capture

Interrupt 19 is the software interrupt that handles the boot drive function. When this
item is set to Enabled, the ROM BIOS of the host adaptors will “capture” Interrupt
19 at boot and allow the drives that are attached to these host adaptors to function as
bootable drives. If this item is set to Disabled, the ROM BIOS of the host adaptors
will not capture Interrupt 19, and the drives attached to these adaptors will not func-
tion as bootable devices. The options are 

Enabled 

and Disabled.

3.3.2

Processor and Clock Options

This submenu allows the user to configure the Processor and Clock settings. 

3.3.2.1 CPU Ratio

Select Manual to manually configure the CPU Ratio. Select Auto to allow the BIOS
to automatically configure the CPU Ratio. The options are 

Auto 

and Manual. 

3.3.2.2 Ratio CMOS Setting (Available when the item-CPU Ratio is set 

to Manual) 

If CPU Ratio is set to Manual (above), this option allows the user to press <+> or <-
> on the keyboard to set the ratio between the CPU Core Clock and the FSB Fre-
quency. The default setting depends on the type of CPU installed on the mother-
board. The default setting is 

[19]

.

3.3.2.3 Clock Spread Spectrum

Select Enable to use the feature of Clock Spectrum support, which will allow the
BIOS to monitor and attempt to reduce the level of Electromagnetic Interference
caused by the components whenever needed. The options are 

Disabled 

and Enabled.

3.3.2.4 Hardware Prefetcher (Available when supported by the CPU)

If set to Enabled, the hardware prefetcher will prefetch streams of data and instruc-

Note:

If an invalid ratio is entered, the AMI BIOS will restore the setting to the

previous state.

Содержание RES-32XR3-S

Страница 1: ...RES 32XR3 S RES 32XR3 S for X8DTL 6 6F Installation Manual Installation Manual 3RU 19 Rack Mount Rugged Enterprise Server with X8DTL 6 and X8DTL 6F Motherboard Configuration Two Quad Core 5500 or Quad...

Страница 2: ...0 0 X e o n C P U s R E S 3 2 X R 3 S f o r X 8 D T L 6 6 F R E S 3 2 X R 3 S f o r X 8 D T L 6 6 F Tw o Q u a d C o r e 5 5 0 0 o r Q u a d S i x C o r e 5 6 0 0 X e o n C P U s R E S 3 2 X R 3 S f o...

Страница 3: ...ance Phone 33 476 14 77 80 Fax 33 476 14 77 89 Themis Computer Americas and Pacific Rim 47200 Bayside Parkway Fremont CA 94538 Phone 510 252 0870 Fax 510 490 5529 World Wide Web http www themis com RE...

Страница 4: ...tered trademark of Themis Computer Inc Intel and Xeon are registered trademarks of Intel Corporation Red Hat is a registered trademark of Red Hat Inc Linux is a registered trademark of Linus Torvalds...

Страница 5: ...iii Themis Computer RES 32XR3 S for X8DTL 6 6F Installation Manual VersionRevisionHistory Version 1 0 September 2010...

Страница 6: ...disconnected from the power sources Therefore the power cords and their connectors must always remain easily accessible Do not set up the device in the proximity of heat sources or in a damp location...

Страница 7: ...Federal Regulations 21 CFR 1040 for the USA and Canadian Radiation Emitting Devices Act REDR C 1370 Electrostatic Discharge ESD A sudden discharge of electrostatic electricity can destroy static sensi...

Страница 8: ...uipment 6 Keep the work area free of non conductive materials such as ordinary plastic as sembly aids and Styrofoam 7 Use field service tools such as cutters screwdrivers and vacuums that are con duct...

Страница 9: ...mental Temperature Control 1 11 1 5 3 System Resource Alert 1 12 1 6 ACPI Features 1 12 1 6 1 Slow Blinking LED for Suspend State Indicator 1 12 1 6 2 Main Switch Override Mechanism 1 13 1 6 3 Wake on...

Страница 10: ...tallation 2 11 2 1 6 Removable 120 mm Fan 2 11 2 1 6 1 Removing and Installing a 120 mm Fan 2 12 2 1 7 Power Supply 2 13 2 1 7 1 Removing a Power Supply 2 13 2 1 7 2 Installing a Power Supply 2 14 2 2...

Страница 11: ...g Available when the item CPU Ratio is set to Manual 3 7 3 3 2 3 Clock Spread Spectrum 3 7 3 3 2 4 Hardware Prefetcher Available when supported by the CPU 3 7 3 3 2 5 Adjacent Cache Line Prefetch Avai...

Страница 12: ...g 3 12 3 3 3 8 Channel Interleave Bank Interleave 3 12 3 3 3 9 Throttling Closed Loop Throttling Open Loop 3 12 3 3 3 10 Intel VT d 3 13 3 3 3 11 SR IOV Support 3 13 3 3 3 12 NUMA Support 3 13 3 3 3 1...

Страница 13: ...ntrol 3 20 3 3 7 5 Redirection After BIOS POST 3 20 3 3 7 6 Terminal Type 3 21 3 3 7 7 VT UTF8 Combo Key Support 3 21 3 3 7 8 Sredir Memory Display Delay 3 21 3 3 8 Hardware Health Monitor 3 21 3 3 8...

Страница 14: ...assword is installed 3 31 3 4 6 Clear User Password Available only when User Password is installed 3 31 3 4 7 Password Check Available when a password is installed 3 31 3 4 8 Boot Sector Virus Protect...

Страница 15: ...A 4 Appendix B Rack Mount Slide Installation B 1 Appendix C Red Hat Enterprise Linux 5 Installation C 1 C 1 Introduction C 1 C 2 Installation C 2 Appendix D Optional Remote On Off Switch D 1 D 1 Remo...

Страница 16: ...xiv Themis Computer RES 32XR3 S for X8DTL 6 6F Installation Manual...

Страница 17: ...tective Access Cover 2 2 Figure 2 2 Remove the Air Flow Deflector Screws 2 5 Figure 2 3 Memory Module Slot Locations 2 6 Figure 2 4 Memory Module Removal 2 6 Figure 2 5 PCI Card Installation 2 7 Figur...

Страница 18: ...XR3 S Rack Mount Slide Installation B 3 Figure C 1 Power On after Linux DVD is Inserted into Drive C 2 Figure C 2 Skip Key C 2 Figure C 3 Welcome Screen C 3 Figure C 4 Language Selection C 3 Figure C...

Страница 19: ...Chassis Manual Matrix AC and DC Power Supplies xx Table 1 1 RES 32XR3 S Motherboard Options 1 2 Table 1 2 RES 32XR3 S Major Features 1 2 Table 1 3 System LEDs 1 8 Table 1 4 I O Connectors 1 9 Table 1...

Страница 20: ...xviii Themis Computer RES 32XR3 S for X8DTL 6 6F Installation Manual Table A 4 RES 32XR3 S VGA Connector Pinout Signals A 3 Table A 5 RJ45 Ethernet Pinout Signals A 4...

Страница 21: ...Interconnect up to 6 4 GT s each the RES 32XR3 S for X8DTL 6 6F supports up to 48 GB 1333 1066 800 MHz DDR3 ECC Registered memory modules The RES 32XR3 S for X8DTL 6 6F supports the SuperMicro X8DTL...

Страница 22: ...tion 4 X8DTN 117024 024 117019 024 Configuration 5 X8DAi X8DA3 117025 024 117020 024 Configuration 6 X8DAH F 117026 024 117021 024 Configuration 7 X8DTU F 117280 024 116970 024 Naming Key X8Dvwxyz z S...

Страница 23: ...7413 024 117417 024 X8DTL iF X8DTL i 2 117410 024 117414 024 117418 024 X8DAL 3 X8DAL i 2 117411 024 117415 024 117419 024 X8SAX 1 117420 024 117421 024 X8ST3 F X8STE 1 117385 024 117422 024 X8STi X8S...

Страница 24: ...FIO 16 Chassis Manual Matrix AC and DC Power Supplies Mother board CPU Soc kets RES 32XR3 FIO Manual P N RES 22XR3 FIO Manual P N X8DAH F 2 117611 024 X8DTU F 2 117664 024 Naming Key X8uvwxyz z Syste...

Страница 25: ...peed server systems Website Information Themis Computer corporate and product information may be accessed on the World Wide Web by browsing the website http www themis com Your Comments are Welcome We...

Страница 26: ...equipment or sharp objects To reduce the risk follow the instructions accompanying this sym bol Warning A warning describes a procedure or action that may cause injury or death to the operator To red...

Страница 27: ...rts dual Intel 1366 pin LGA 64 bit XeonTM 5500 5600 Series processors each with a QPI Quick Path Intercon nect up to 6 4 GT s and 48 GB 1333 1066 800 MHz ECC Registered memory mod ules Its many comput...

Страница 28: ...2x IOH 24D Memory z 6 240 pin DIMM sockets z Up to 48 GB of total memory z 1333 1066 800 MHz DDR3 ECC Registered Memory Modules Peripheral Support z Eight SAS ports from the motherboard RAID 0 1 5 10...

Страница 29: ...ESI CLINK PCI E X8 Slot4 Gen2 X4 Gen2 X4 Gen2 X8 Gen2 X8 DMI CLINK PORT1 4 PORT5 PORT6 ICH10R ATMEL AT25DF321 SAS 1 SAS 2 SAS 3 SAS 4 SAS 6 SAS 7 SAS 5 LSI SAS2008 B0 PCI E x16 Slot6 PCI E x8 Slot5 PC...

Страница 30: ...I O connectors see Figure 1 5 on page 1 7 Major internal components of the RES 32XR3 S for X8DTL 6 6F can be seen in Figure 1 3 External Features of RES 32XR3 S Front and Rear Front View Doors Open Du...

Страница 31: ...of Figure 1 4 on page 1 6 1 2 System LEDs and I O Connectors All RES 32XR3 S system LEDs are located on the front panel see A Figure 1 5 on page 1 7 all I O connectors are located on the rear panel s...

Страница 32: ...nt PCI Slot 1 2 3 4 5 6 PCI 33MHz PCI E 2 0 x8 in x16 slot PCI E x4 in an x8 slot PCI E 2 0 x4 in x8 slot PCI 33MHz Storage Drive 1 of 8 CD DVD Combo Drive Housing 120 mm Fan 1 of 2 Air Flow Deflector...

Страница 33: ...onnectors A B LEDs NIC1 NIC2 Hard Disk Drives Power ON OFF Button Power Fail PS1 Overheat Fan Fail Power Fail PS2 C ENET2 ENET1 Front Panel Doors Open I O Connectors PS 2 Keyboard IPMI Dedicated LAN C...

Страница 34: ...ailure in the right power supply Overheat Fan Fail Normally OFF RED light when tem perature limits are ex ceeded z Warns that the system is exceeding specified temperature parameters The CPU overheat...

Страница 35: ...ar panel z 1 USB on board z 2 USB internal headers z Total of 5 USB 2 0 compliant USB ports COM 1 Serial Port z One DB9 male connector on rear panel to attach a serial device to the COM 1 port Note An...

Страница 36: ...ink Each link consists of 20 pairs of unidirectional differential lanes for transmitting and receiving in addition to a differential forwarded clock A full width QPI link pair provides 84 signals Each...

Страница 37: ...Monitoring This section describes the PC health monitoring features of the RES 32XR3 S for X8DTL 6 6F motherboard All have an onboard System Hardware Monitor chip that supports PC health monitoring An...

Страница 38: ...e ACPI specifica tion defines a flexible and abstract hardware interface that provides a standard way to integrate power management features throughout a PC system including its hard ware operating sy...

Страница 39: ...at daily LAN traffic is kept to a min imum and users are not interrupted The motherboard has a 3 pin header WOL to connect to the 3 pin header on a Network Interface Card NIC that has WOL capa bility...

Страница 40: ...also provides LPC interface to control Super IO functions The WPCM450 is connected to the network via an external Ethernet PHY module The WPCM450 communicates with onboard components via six SMBus in...

Страница 41: ...to 149 F z 40 to 70 C 40 to 158 F Relative Humiditya Operating Non Operating z 8 to 95 non condensing z 5 to 95 non condensing Maximum Wet Bulba Operating Non Operating z 55 C non condensing z 70 C n...

Страница 42: ...r Table 1 6 RES 32XR3 S Electrical Specifications Parameter Description AC 120 volts 750W DC 48 volts 750W DC 28 volts 500W Input Power typical z 420 watts typical a z 420 watts typical a z 450 watts...

Страница 43: ...ion 1 9 3 2 Electrostatic Discharge The RES 32XR3 S for X8DTL 6 6F is designed to tolerate electrostatic pulses up to 15 kilovolts KV with no impact on system operation 1 9 3 3 Noise The RES 32XR3 S c...

Страница 44: ...ure 1 6 RES 32XR3 S for X8DTL 6 6F with Front Sound Baffle Installed Front View Front Sound Baffle A A Note All RES systems are shipped with BIOS fan speed set to the quietest mode The default fan spe...

Страница 45: ...ors of the RES 32XR3 S requires remov ing the front sound baffle To do this loosen the two 2 captive knurled Phillips screws holding the baffle to the chassis see A in Figure 1 7 page 1 19 and remove...

Страница 46: ...cards Removing the protective top cover for access to the interior requires that the rear sound baffle be totally removed this can be done with the baffle door closed To do this five 5 M3x4 flathead...

Страница 47: ...nds 17 3 kg 1 10 1 Accessory Kit Each RES 32XR3 S for X8DTL 6 6F is packaged with an Accessory Kit consist ing of the following items A A Power cord Retainer Bracket B Two AC Power Cords C Two Storage...

Страница 48: ...ES 12XR3 19 5 lbs 8 9 kg 2 20 Includes z All CPU sockets filled z 6 DIMMs z 2 storage drives z 2 PCI cards z 1 CD RW DVD ROM drive z 2 power supplies RES 12XR3 S 17 lbs 7 7 kg 2 17 RES 11XR3 16 5 lbs...

Страница 49: ...ion and proceed directly to page 2 9 page 2 11 or page 2 13 respectively Replacement of motherboard components requires removal of the protective cover 2 1 1 Remove Protective Top Cover To access a mo...

Страница 50: ...tabs underneath that fit under slots on the chassis top edges see B Figure 2 1 Remove the cover by sliding it toward the rear until it is free of these chassis slots 3 Store the cover in a safe place...

Страница 51: ...DIMMS Pins per DIMM X8DTL 6 and X8DTL 6F 48 GB Yes 1333 1066 800 6 240 Caution Exercise extreme caution when installing or removing FBD Memory Modules to prevent any possible damage Table 2 2 Memory P...

Страница 52: ...at both ends of the slot see Figure 2 4 on page 2 6 then pulling the old module directly up from the slot until it is free of the connector see Figure 2 4 on page 2 6 3 Before inserting a new memory...

Страница 53: ...lation Procedures 2 5 Themis Computer 4 If all the memory modules have been replaced in the system replace the air flow diverter and secure it with the five screws previously removed Figure 2 2 Remove...

Страница 54: ...Themis Computer Figure 2 3 Memory Module Slot Locations Figure 2 4 Memory Module Removal P2 DIMM 1A Branch 0 Branch 1 Branch 2 Branch 0 Branch 1 Branch 2 P1 DIMM 1A P1 DIMM 3A P1 DIMM 2A P2 DIMM 3A P...

Страница 55: ...CI PCI Express slots see Figure 2 5 2 1 3 1 Installing Cards Perform the following steps to install a PCI card Figure 2 5 PCI Card Installation 5 Slot 1 PCI 33MHz Slot 5 PCI E 2 0 x4 in x8 slot Slot 3...

Страница 56: ...position over the PCI card I O panels and tighten the captive knurled screw on the PCI card clamp 7 Attach any internal I O cables to the installed PCI cards and carefully fold and tuck any exposed r...

Страница 57: ...new lithium battery 1 Tilt the replacement battery into the empty socket so that it is angled under the battery latch see B Figure 2 7 2 Carefully press down on the battery until it clicks firmly into...

Страница 58: ...rew counter clockwise and pull both doors away from the chassis The accessory kit shipped with your RES 32XR3 S for X8DTL 6 6F contains two barrel lock keys This provides you the option of unlocking l...

Страница 59: ...clockwise presuming the storage drive is locked see A in Figure 2 10 on page 2 11 4 Firmly push in the latch lock until the latch handle releases away from the drive see B in Figure 2 10 5 Grab the l...

Страница 60: ...es into contact with the RES 32XR3 S for X8DTL 6 6F chassis 4 When the drive is fully inserted in its slot insert the key into the barrel lock and turn it 45 degrees counter clockwise The drive is now...

Страница 61: ...left hand index finger With the right hand index finger press on the right hand side of the fan and pull the fan directly upward from the RES 32XR3 S for X8DTL 6 6F chas sis 3 When the fan is removed...

Страница 62: ...Installation Manual 2 1 7 Power Supply Each of the two load sharing N 1 redundant power supplies can be hot swapped while the system is still on and operational 2 1 7 1 Removing a Power Supply Perfor...

Страница 63: ...of the power supply locking lever Figure 2 12 The RES 32XR3 S for X8DTL 6 6F Power Supply Locking Mecha nism Extraction Push right to release power supply Handle Power Supply Locking Lever Power LED...

Страница 64: ...empty slot with the extraction handle facing to the right see Figure 2 12 on page 2 13 2 Push the power supply carefully into its slot until it is firmly seated a click will be heard when the locking...

Страница 65: ...nt slides have been installed on the sides of the chassis see fol lowing section 2 2 2 Rack Mount Slides Optional Rack Mount Slides can be mounted on each side of the RES 32XR3 S for X8DTL 6 6F for th...

Страница 66: ...r socket on each power supply see Fig ure 2 14 2 3 2 Turning the System On 1 Plug the AC power cord from each of the RES 32XR3 S for X8DTL 6 6F power supplies into a live AC outlet The LED on each pow...

Страница 67: ...page 2 10 Changes may be made through the BIOS 2 Connect a multiscan monitor to the VGA connector 3 Attach a PS 2 keyboard and mouse to the appropriate connectors on the rear I O panel of the RES 32XR...

Страница 68: ...15 page 2 16 for at least four 4 sec onds This will shut down the system and turn off the POWER LED As an alternative a modern operating system Windows 9x or newer and Linux for example can turn off t...

Страница 69: ...Each main BIOS menu option is described in this manual The Main BIOS setup menu screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be...

Страница 70: ...s the memory is being tested press the Delete key to enter the main menu of the AMI BIOS Setup Utility From the main menu you can access the other setup screens An AMI BIOS identification string is di...

Страница 71: ...etup screen is shown below 3 2 1 System Time System Date Use this option to change the system time and date Highlight System Time or System Date using the arrow keys Key in new values through the keyb...

Страница 72: ...splays the type of CPU used in the motherboard Speed This item displays the speed of the CPU detected by the BIOS Physical Count This item displays the number of processors installed in your system as...

Страница 73: ...led this option will skip certain tests during POST to reduce the time needed for system boot The options are Enabled and Disabled 3 3 1 2 Quiet Boot This option allows the bootup screen options to be...

Страница 74: ...nabled 3 3 1 7 Hit Del Message Display This feature displays Press DEL to run Setup during POST The options are Enabled and Disabled 3 3 1 8 Watch Dog Function If enabled the Watch Dog Timer will allo...

Страница 75: ...l to manually configure the CPU Ratio Select Auto to allow the BIOS to automatically configure the CPU Ratio The options are Auto and Manual 3 3 2 2 Ratio CMOS Setting Available when the item CPU Rati...

Страница 76: ...ring 3 3 2 7 Intel Virtualization Technology Available when supported by the CPU Select Enabled to enable Virtualization Technology support to allow one platform to run multiple operating systems and...

Страница 77: ...Please refer to Intel s web site for detailed information The options are Disabled and Enabled 3 3 2 12 Intel TurboBoost Technology Available when EIST Technolo gy is enabled Select Enabled to enable...

Страница 78: ...he performance of TOE devices For this motherboard the TOE device is built inside the Intel South Bridge chip This feature is supported only by some types of processors The options are Enabled and Dis...

Страница 79: ...3 3 4 Memory Frequency This feature forces a DDR3 frequency slower than what the system has detected The available options are Auto Force DDR 800 Force DDR 1066 and Force DDR 1333 3 3 3 5 Memory Mode...

Страница 80: ...s are Disabled and Enabled If Enabled the following items will appear Hysteresis Temperature Closed Loop only Temperature Hysteresis is the temperature lag in degrees Celsius after the set DIMM temper...

Страница 81: ...e DMAR ACPI Tables This feature offers fully protected I O resource sharing across the Intel plat forms providing the user with greater reliability security and availability in net working and data sh...

Страница 82: ...ectable unless the item above USB Functions is set to Disabled 3 3 3 17 Legacy USB Support Select Enabled to use Legacy USB devices If this item is set to Auto Legacy USB support will be automatically...

Страница 83: ...s allow the user to set the parameters of Primary IDE Master Slave Secondary IDE Master Slave Third and Fourth IDE Master slots Hit Enter to activate the following submenu screen for detailed options...

Страница 84: ...IO mode 1 It has a data transfer rate of 5 2 MBs Select 2 to allow the AMI BIOS to use PIO mode 2 It has a data transfer rate of 8 3 MBs Select 3 to allow the AMI BIOS to use PIO mode 3 It has a data...

Страница 85: ...to use Ultra DMA mode 4 It has a data transfer rate of 100 MBs Select UDMA5 to allow the BIOS to use Ultra DMA mode 5 It has a data transfer rate of 133 MBs Select UDMA6 to allow the BIOS to use Ultr...

Страница 86: ...n enabled the BIOS uses PCI bus mastering for reading writing to IDE drives The options are Disabled and Enabled 3 3 5 5 PCI Express I O Performance Some add on cards perform faster with the coalesce...

Страница 87: ...e user to specify which graphics controller to be used as the primary boot device The options are Onboard VGA and other 3 3 6 Super IO Device Configuration 3 3 6 1 Serial Port1 Address Serial Port2 Ad...

Страница 88: ...ddress and IRQ of the serial port specified above The default setting is 3F8h 4 3 3 7 3 Serial Port Mode This feature allows the user to set the serial port mode for Console Redirection The options ar...

Страница 89: ...er to monitor system health and review the status of each item as displayed 3 3 8 1 CPU Overheat Alarm This option allows the user to select the CPU Overheat Alarm setting which deter mines when the C...

Страница 90: ...tervention No action required Medium The processor is running warmer This is a precautionary level and generally means that there may be factors contributing to this condition but the CPU is still wit...

Страница 91: ...agement please refer to Intel s Web site at www Intel com 2 To avoid possible system overheating please provide adequate airflow to the system System Temperature The system temperature will be display...

Страница 92: ...h playback and reducing the dependency on other timestamp calculation devices such as an x86 RDTSC Instruc tion embedded in the CPU The High Performance Event Timer is used to replace the 8254 Program...

Страница 93: ...to ACPI s website for further explanation http www acpi info 3 3 10 Trusted Computing 3 3 10 1 TCG TPM Trusted Platform Module Support Select Yes on this item and enable the TPM jumper on the motherb...

Страница 94: ...terface IPMI is a set of common interfaces that IT administrators can use to monitor system health and to manage the system as a whole For more information on the IPMI specifications please visit Inte...

Страница 95: ...3 13 Set LAN Configuration Set this feature to configure the IPMI LAN adapter with a network address as shown in the following graphics 3 3 13 1 Channel Number Enter the channel number for the SET LAN...

Страница 96: ...work which subnet this machine belongs to The value of each three digit number separated by dots should not exceed 255 Gateway Address This is the IP address of the gateway in the network This is usua...

Страница 97: ...and 10 Sec 3 3 15 Event Log Configuration 3 3 15 1 View Event Log Use this option to view the System Event Log 3 3 15 2 Mark all events as read This option marks all events as read The options are OK...

Страница 98: ...word This item indicates if a Supervisor password has been entered for the system Not Installed means a Supervisor password has not been used 3 4 2 User Password This item indicates if a user password...

Страница 99: ...ser Password is installed Select this feature and press Enter to access the submenu and then type in a new User Password 3 4 6 Clear User Password Available only when User Password is installed This i...

Страница 100: ...ty for the Boot Device The settings are 1st boot device 2nd boot device 3rd boot device 4th boot device 5th boot device and Disabled 1st Boot Device 2nd Boot Device 3 5 2 Storage Drives This feature a...

Страница 101: ...The settings are 1st boot device 2nd boot device and Disabled 1st Drive 2nd Drive 3 5 4 CD DVD Drives This feature allows the user to specify the boot sequence from available CD DVD Drives 3 5 5 Retry...

Страница 102: ...ion to save the changes and exit the BIOS Setup Utility and reboot the computer so the new system configuration parameters can take effect Select Save Changes and Exit from the Exit menu and press Ent...

Страница 103: ...sts of a boot sector block and a main BIOS code block a main BIOS image The boot sector block contains critical BIOS code including memory detection and recovery code to be used to flash a new BIOS im...

Страница 104: ...e beep codes to indicate that the BIOS ROM file is being updated 4 When BIOS flashing is completed the computer will reboot Do not interrupt the flashing process until it is completed 3 7 2 Boot Secto...

Страница 105: ...terminal program 2 Make sure that the new BIOS Image file is accessible for the host system 3 Start the terminal program on the host system and create a new connection Use the following communication...

Страница 106: ...OS file is being uploaded 7 To use Hyper Terminal to transfer the XModem protocol by using the Send File dialog under the Transfer menu follow the instructions below to com plete XModem transfers a Se...

Страница 107: ...remote BIOS flash is completed the system will reboot Figure 3 7 ROM File Extraction Figure 3 8 Flash Recovery Note AMIBIOS Serial Flash will work with any terminal communications pro gram that suppo...

Страница 108: ...u should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the...

Страница 109: ...6 6F A 1 PS 2 Keyboard and Mouse The RES 32XR3 S provides a 6 pin female mini DIN connector for the PS 2 key board and another for the PS 2 mouse Signals for both connectors are defined in Table A 1 T...

Страница 110: ...3 Serial Port The RES 32XR3 S supports one male DB9 serial port connector COM 1 on the rear I O panel see Figure A 2 for a pinout and a second serial header on the moth erboard COM 1 pinout signal des...

Страница 111: ...Symbol VGA Display Port 1 5 6 10 11 15 Table A 4 RES 32XR3 S VGA Connector Pinout Signals Pin VGA Signal Description Pin VGA Signal Description 1 RED OUT Red signal output 9 NC Key no pin 2 GREEN OUT...

Страница 112: ...net LAN port on the RES 32XR3 S rear I O panel has identical pinout and signal descriptions as the LAN 1 and LAN 2 Ethernet ports described in the previous Section A 5 Gigabit Ethernet LAN Ports Figur...

Страница 113: ...ins five threaded screw holes on each side to accom modate 8 32 size screws included with the rack mount slide kit steel slides require four mounting holes and aluminum slides require three mounting h...

Страница 114: ...will be installed this can vary from 24 to 30 3 Using the depth of the equipment rack adjust and attach the front and rear slide brackets to the outside slide section using the screws washers and nut...

Страница 115: ...et to the outside slide section with screws Outside slide section washers and nuts included in slide kit Attach the rear long slide bracket to the outside slide section with screws washers and nuts in...

Страница 116: ...Themis Computer RES 32XR3 S for X8DTL 6 6F Installation Manual B 4...

Страница 117: ...me to the Red Hat Enterprise Linux Installation Guide This guide contains useful information to assist you during the installation of Red Hat Enterprise Linux via DVD device from fundamental concepts...

Страница 118: ...system you will see the first installation screen with a boot prompt press ENTER to begin installation see Figure C 1 on page C 2 C 2 2 Step 2 Step 2 Press the tab key to move focus to the Skip key th...

Страница 119: ...to continue C 2 4 Step 4 Step 4 Using your mouse select a language to use for the installation The lan guage you select here will become the default language for the operating system once it is insta...

Страница 120: ...ave made the selection click Next to continue see Figure C 5 on page C 4 C 2 6 Step 6 Step 6 Enter the installation number if you don t have an installation number select the Skip Entering Installatio...

Страница 121: ...ing the Create custom layout option of Disk Druid The first three options allow you to perform an automated installation without hav ing to partition your drive s yourself If you do not feel comfortab...

Страница 122: ...h as Windows VFAT or NTFS partitions Remove Linux partitions on selected drives and create default layout select this option to remove only Linux partitions partitions created from a previous Linux in...

Страница 123: ...itions if they do not meet your needs see Figure C 8 on page C 6 Click Next once you have made your selections to proceed C 2 9 Step 9 Step 9 If you chose one of the automatic partitioning options and...

Страница 124: ...loader such as Partition Magic or Microsoft s TLDR If you want to set up a Boot Loader Password or to configure more advanced boot loader options select the appropriate check box see Figure C 10 on p...

Страница 125: ...your computer s BIOS and is the earliest point at which the boot loader can take control of the boot process If you install it in the MBR when your machine boots GRUB presents a boot prompt You can th...

Страница 126: ...ging the drive order may be useful if you have multiple SCSI adapters or both SCSI and IDE adapters and you want to boot from the SCSI device Click Next C 2 12 Step 12 Step 12 The installation program...

Страница 127: ...fix for IPv6 of the device via DHCP or manu ally if DHCP is not selected and you can choose to activate the device at boot time If you select Activate on boot your network interface is started when yo...

Страница 128: ...f the world see Figure C 14 on page C 12 From here there are two ways for you to select your time zone Using your mouse click on the interactive map to select a specific city represented by a yellow d...

Страница 129: ...t steps during your installation Your root account is similar to the administrator account used on Windows NT machines The root account is used to install packages upgrade RPMs and perform most system...

Страница 130: ...m The Package Installation Defaults screen appears and details the default package set for your Red Hat Enterprise Linux installation This screen varies depending on the version of Red Hat Enterprise...

Страница 131: ...on of the two To select a component click on the checkbox beside it Select each component you wish to install Once a package group has been selected if optional components are available you can click...

Страница 132: ...hoice you get one last chance to go back before starting the installation process Click Next if you re happy with your choices or click Back to make changes see Figure C 18 on page C 16 Click Next C 2...

Страница 133: ...normal power up sequence has completed the graphical boot loader prompt appears at which you can do any of the following things Press Enter causes the default boot entry to be booted Select a boot lab...

Страница 134: ...ogin prompt or a GUI login screen appears if you installed the X Window System and chose to start X automatically see Figure C 21 on page C 18 C 2 22 Step 22 Step 22 Once logged in you are ready to us...

Страница 135: ...nal switch from which to remotely turn the RES 32XR3 S for X8DTL 6 6F on or off are able to order a Remote On Off Switch module that is easily installed in an available storage drive bay see Figure D...

Страница 136: ...racefully shut down the system through the BIOS pressing the switch OFF for 4 seconds or more results in a hard power off equivalent to pulling the plug on the system D 2 Remote On Only Configuration...

Страница 137: ...mage in transit Equipment should be wrapped in a moisture resistant covering and placed either in double boxes or in boxes with crush resistant insulation between the equipment and the outer walls of...

Страница 138: ...al about the equipment in accordance with the fol lowing instructions See Figure E 2 page E 3 Inspect the original packing materials for serviceability Place one crush resistant layer open side down m...

Страница 139: ...nt Press down on the top layer to firmly compress the layers around the equip ment and allow for the box flaps to be closed Seal the top of the box with strong packing tape wrapping the tape completel...

Страница 140: ...E 4 Themis Computer RES 32XR3 S for X8DTL 6 6F Installation Manual...

Страница 141: ...iguration One Table Chipset 1 2 Memory 1 2 Processors 1 2 Configuration system 2 17 CPU 1 1 D Dimensions chassis 1 2 disk drives removal 2 10 E ECC SDRAM memory modules 2 4 Electrical Specifications 1...

Страница 142: ...CPU CPU1 Installed 2 3 Memory Population for One CPU CPU2 Installed 2 3 N Noise 1 17 Noise baffle 1 17 Noise muffler 1 17 noise reduction 1 17 noise specification 1 17 Notes xxi O Opening the RES 32XR...

Страница 143: ...xx Shock endurance 1 2 Sidebars xxi slides rack mount xx slimline drive 1 2 Sound Baffle Installed front 1 18 1 19 rear 1 20 Specifications Altitude 1 15 BTU Rating 1 16 Dimensions 1 14 Electrostatic...

Страница 144: ...RES 32XR3 S for X8DTL 6 6F Installation Manual Index 4 Themis Computer X X8DTL 6F Motherboard Block Diagram 1 3 Xeon processors 1 1...

Страница 145: ...ThemisComputer 47200BaysideParkway Fremont CA94538 Attn PublicationsDepartment Place Stamp Here Fold here tape at top to seal...

Страница 146: ...mproved ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ____________...

Отзывы: