background image

 

 

ECHO PELLET E.I. 

II

 

Pellet Heater Owner's Manual 
Installation and Operating Instructions 

 

 
 

 
 
 
 
 
 
 
 

SAFETY NOTICE 

 

 

HEATER MUST BE PROPERLY INSTALLED AND MAINTAINED OR A HOUSE FIRE MAY 
RESULT. 

 

FOR YOUR SAFETY, FOLLOW THE INSTALLATION INSTRUCTIONS. 

 

CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION 
INSPECTION AND PERMIT REQUIREMENTS. 

 

FAILURE TO COMPLY WITH OWNER'S MANUAL INSTRUCTIONS WILL VOID 
WARRANTY AND COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN 
DEATH. 

PLEASE LEAVE THIS MANUAL WITH THE OWNER!! 

Warnock Hersey Test Labs, Middleton, WI 

TH-REF-SLS-230 Rev. A 

Please read this entire manual before installation and use of the pellet fuel-burning room heater. Failure to follow these instructions 

could result in property damage, bodily injury or even death. 

 

Made in the USA by: 

 

 

Содержание Echo Pellet E.I. II

Страница 1: ...ALLATION INSPECTION AND PERMIT REQUIREMENTS FAILURE TO COMPLY WITH OWNER S MANUAL INSTRUCTIONS WILL VOID WARRANTY AND COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH PLEASE LEAVE THIS MANU...

Страница 2: ...Light 16 Hopper clean out 18 filling 14 Igniter Removal 28 Installation 7 battery 16 clean out tee 7 distance to openings 7 floor protection 7 pipe configuration 8 pipe connections 11 venting requirem...

Страница 3: ...ure 3 7 Figure 4 8 Figure 5 9 Figure 6 10 Figure 7 11 Figure 8 13 Figure 9 14 Figure 10 14 Figure 11 15 Figure 12 18 Figure 13 Replacement Parts List 21 Figure 14 Circuit Board Diagram 22 Figure 15 El...

Страница 4: ...ECHO PELLET E I II PELLET HEATER 4 LABORATORY LISTING LABEL...

Страница 5: ...d container of ashes should be placed on a non combustible floor or the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwi...

Страница 6: ...ustion and ventilation air The air inlet must remain unrestricted while unit is in use Outside air connection is made at the air intake located on the rear of the stove see Figure 2 The Outside Air Ki...

Страница 7: ...e hearth pad must be used if installed on a carpet wood floor or other comb ustible material see FIGURE 3 Maintain 6 152mm beyond the front and beyond each side of the fuel loading and ash removal ope...

Страница 8: ...ECHO PELLET E I II PELLET HEATER 8 FIGURE 4...

Страница 9: ...ECHO PELLET E I II PELLET HEATER 9 FIGURE 5...

Страница 10: ...ECHO PELLET E I II PELLET HEATER 10 FIGURE 6...

Страница 11: ...ar cleaning see FIGURE 4 Whenever the pipe run in any installation is 10 feet or more the use of 4 inch Type L vent pipe is required Horizontal runs must be limited to 2 feet On vertical runs on an ex...

Страница 12: ...mostat manufacturer s instructions 3 Locate thermostat approximately 10 to 12 feet from heater or in an area that requires steady temperature Run thermostat wires from heater to thermostat along wall...

Страница 13: ...ECHO PELLET E I II PELLET HEATER 13 FIGURE 8...

Страница 14: ...9 Use good quality pellets that give a vibrant yellow flame with little or no soot Poor quality pellets will burn rich with black sooty smoke and ash will accumulate quickly IMPORTANT The quality of p...

Страница 15: ...nsure the built in thermostat terminals on the bottom of the stove are used See FIGURE 8 It is recommended the heater is run on High for approximately 30 minutes to get the heat exchanger hot before t...

Страница 16: ...k draft If there is problem with the fan guard becoming blocked due to dust and lint build up then this light will come on and stay steady red The feed will shut off and the stove will shut down when...

Страница 17: ...he automatic ignition feature will not work on DC power only The automatic ignition feature will not work on DC power only Contact your Dealer for manual start instructions MAINTENANCE PROCEDURES CAUT...

Страница 18: ...d every four to six weeks or whenever the Clean mode on the Control Panel is utilized a Fly ash can also accumulate in the vent pipe Inspect the exhaust system frequently to maintain free flow of exha...

Страница 19: ...E POWER OFF empty the hopper and check the feed chute to see what is causing the jam ENSURE THE POWER IS OFF Remove any foreign material or object and restart the heater CAUTION Keep fingers and hands...

Страница 20: ...ian If the fly ash build up is excessive try another pellet brand In most climates the pellets and fly ash can absorb moisture from the air and create creosote and a severe clogging problem The heater...

Страница 21: ...ECHO PELLET E I II PELLET HEATER 21 FIGURE 13 REPLACEMENT PARTS LIST...

Страница 22: ...ECHO PELLET E I II PELLET HEATER 22 FIGURE 14 CIRCUIT BOARD DIAGRAM Type 2 Thermo Hi Lo Type 1 Thermo On Off...

Страница 23: ...ECHO PELLET E I II PELLET HEATER 23 FIGURE 15 ELECTRICAL SCHEMATIC WIRING DIAGRAM 250 VAC 250 VAC...

Страница 24: ...heat exchanger tubes both sides using a pellet vac or shop vac CAUTION Do not use a household vacuum cleaner 4 Connect vinyl clean out tube to pellet vac or shop vac An adaptor must be used to connec...

Страница 25: ...ue high temp safety sensor that will shut the stove off if there is a down draft blocked flue or high temperature condition If installing the stove on the side of the house that is hit by prevailing w...

Страница 26: ...ECHO PELLET E I II PELLET HEATER 26 APPENDIX B E I FIREPOT ASSEMBLY...

Страница 27: ...re 2 The Air Intake Damper control located on the air intake module see FIGURE 2 regulates the amount of combustion air being fed to the pellet fire pot For example a high vertical run of pipe over 10...

Страница 28: ...ECHO PELLET E I II PELLET HEATER 28 APPENDIX D IGNITER REMOVAL...

Страница 29: ...amages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights that vary from state to state WARRANTY WORK If you find this unit to be defective in mate...

Страница 30: ...ECHO PELLET E I II PELLET HEATER...

Отзывы: