27
1.
Horizontal Operation
Align the tripod and screw the TPL tight using the tripod
screw. The precision of alignment affects the size of the
slope range. Use the On/Off switch to switch on the
device.
The levelling indicator flashes on the lit display.
If the tripod head is sloping by more than 5°, this is
indicated by the laser beam flashing quickly and the
alarm symbol being displayed.
In this case, switch off the unit and align the tripod more
carefully.
Once horizontal levelling is completed, the laser beam
starts to rotate.
2.
Vertical Operation/Alignment Mode
Set up the laser or fasten it to the tripod such that the
keypad is facing upwards. If necessary, use the 5/8“nut
to screw it on the tripod. Use the On/Off button to switch
on the laser. For more information, refer to point 1.
Use the arrow keys to align the laser beam. Pressing
the arrow key and holding it down speeds up alignment
of the laser beam.
If the traverse path is exceeded while aligning, this is
indicated by a change in the arrangement of the bars,
by a quickly flashing warning symbol and by the laser
beam.
You can clear the end stops again using the arrow keys.
_ _ _
_ - _
-
_
-
Содержание Vision 2N Align
Страница 1: ...VISION 2N Gebrauchsanleitung DE Instruction manual EN Instructions de service FR ...