NOTE
Migrating a RAID volume could take several hours to complete
With RAID level migration function, it has two different type “On line” and “Off line”
alone with limitation as listed below.
1.
During RAID level migration, it is not allowed reboot or shutdown system.
2.
Off line RAID level migration, all services will stop and data is inaccessible.
3.
To have ZFS file system created doing on line RAID level migration from R1
to R5 or R1 to R6, the all services will restart and volumes “user data”,
“iSCSI” and “Target USB” are read only during operation.
4.
To have ext3 and XFS file system created doing on line RAID level
migration from R1 to R5 or R1 to R6, the all services will restart and
volumes “iSCSI” and “Target USB” are read only but “user data” is capable
read / write during operation.
5.
The other combination to make as “On line” can have read / write work as
normal.
Below is a table listing of possible RAID migration schemes:
To
From
RAID 0
RAID 5
RAID 6
RAID
0
[OFFLINE]
[RAID 0] HDDx2 to [RAID 0] HDDx3
[RAID 0] HDDx2 to [RAID 0] HDDx4
[RAID 0] HDDx3 to [RAID 0] HDDx4
[OFFLINE]
[RAID 0] HDDx2 to [RAID 5] HDDx3
[RAID 0] HDDx2 to [RAID 5] HDDx4
[RAID 0] HDDx3 to [RAID 5] HDDx4
X
RAID
1
[OFFLINE]
[RAID 1] HDDx2 to [RAID 0] HDDx2
[RAID 1] HDDx2 to [RAID 0] HDDx3
[RAID 1] HDDx2 to [RAID 0] HDDx4
[RAID 1] HDDx3 to [RAID 0] HDDx4
[ONLINE]
[RAID 1] HDDx2 to [RAID 5] HDDx3
[RAID 1] HDDx2 to [RAID 5] HDDx4
[RAID 1] HDDx3 to [RAID 5] HDDx4
[ONLINE]
[RAID 1] HDDx2 to [RAID 6] HDDx4
[RAID 1] HDDx3 to [RAID 6] HDDx4
RAID
5
X
[ONLINE]
[RAID 5] HDDx3 to [RAID 5] HDDx4
X