Theben TIMEGUARD PDFM361AB Скачать руководство пользователя страница 7

6

6. Connection Diagram

C2  C1

L N N

P/S

L

N

Channel

1 Load

Push

Button

Channel 2 Load

Volt Free Input

L N N

P/S

L

N

Channel

1 Load

Push

Button

230V AC 50Hz Mains Supply

Live (Brown or Red) to L
Neutral (Blue or Black to N

PDFM361AB: Wiring Configuration 

Load

Switched Live 
(Brown or Red) to
Neutral (Blue or Black to N

PDFM361AB

PDFM362AB

Channel 1: 230V AC 50Hz Only
Live (Brown or Red) to L
Neutral (Blue or Black to N
Channel 2: Volt Free Input to C1
(5-230V AC 50Hz or 5-30V DC 
5A MAX) or 73W Motor

PDFM362AB: Wiring Configuration 

Load

Switched Live Channel 1 
(Brown or Red) to
Switched Live Channel 2
Volt Free Output to C2
(Terminal C2 will refelct the
supply from terminal C1)

Supply (Mains + Volt Free)

Содержание TIMEGUARD PDFM361AB

Страница 1: ...Presence Detector With Model PDFM361AB 1 Channel Model PDFM362AB 2 Channel I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s Optional Absence Detection 360 Flush Mount PIR...

Страница 2: ...eaker turned off It is recommended that a qualified electrician is consulted or used for the installation of this PIR and install in accordance with the current IEE wiring and Building Regulations Che...

Страница 3: ...the latest directiives Construction Polycarbonate Dimensions H x W x D 105mm x 105mm x 67mm PIR Ceiling Projection 23 5mm Note Only PDFM362AB supports 2 channel Note Absence mode can only be triggere...

Страница 4: ...ensure the best performance from the PIR and the appointed approach path Effective Approach Path ACROSS Ineffective Approach Path TOWARDS Avoid positioning the PIR near any sources of heat in and aro...

Страница 5: ...itch should be installed to enable the power to be switched ON and OFF to the PIR This allows the unit to be easily switched OFF for maintenance purposes Mark the position of the 68mm diameter hole cu...

Страница 6: ...re sleeved See Section 6 Connection Diagram When wiring is complete close the door entry access points to clamp the cable securely into place Tighten the screws to the door entry points and ensure not...

Страница 7: ...61AB Wiring Configuration Load SwitchedLive BrownorRed to Neutral BlueorBlacktoN PDFM361AB PDFM362AB Channel1 230VAC50HzOnly Live BrownorRed toL Neutral BlueorBlacktoN Channel2 VoltFreeInputtoC1 5 230...

Страница 8: ...ion area when the PIR is triggered and the load will turn ON for the minimum set amount of time Once you are happy with the pickup area of the PIR you can set the Lux dial in the anticlockwise directi...

Страница 9: ...ards as long as detection in the area has constant movement the PIR will continue to keep the luminaire or attached load swtiched on until the subject has moved out of the detection area and the time...

Страница 10: ...IR10AB is an optional remote control that is sold separately If absence detection is required the IR10AB will be needed to change modes over LUX control adjustment Auto mode only Time delay adjustmen...

Страница 11: ...de of the UK All shipping costs are to be paid in advance before a replacement is sent Problem Cause Solution False activation Luminaire switches on for no apparent reason Heat sources as described in...

Страница 12: ...com or call the helpdesk on 020 8450 0515 Qualified Customer Support Coordinators will be online to assist in resolving your query For a product brouchure please contact Timeguard Limited Victory Par...

Отзывы: