6.  Setting 

The motion detector has two potentiometers underneath for 

setting the time (min) and brightness (lux).

Min

Set brightness (lux)

You can set different brightness values (lux) with the  

potentiometer.

If you want to change the preset brightness (15 lux default)

†

†

Set potentiometer to desired brightness (5 – 1000 lux).

teach-in

1000 Lux

5 Lux

500 Lux

7 Lux

100 Lux

10 Lux

15 Lux

50 Lux

15 Lux

or want a specific brightness value to be learned using the 

teach-in function

†

†

At the desired brightness set the potentiometer to  

The value will be learned after 15 s.

Содержание theLuxa S150 BK

Страница 1: ...hould only be carried out by a pro fessional electrician WARNING The device conforms with EN 60669 2 1 when correctly installed IP 55 in accordance with EN 60529 Designated use Motion detector for aut...

Страница 2: ...otentiometers for setting time min and bright ness lux Motion detector with sensor head 3 Connection WARNING Danger of death through electric shock Disconnect power source Cover or shield any adjacent...

Страница 3: ...3 The device can be manually activated with a circuit breaker After releasing the button return of power the device swit ches on for at least 40 secs or for the time set on the device...

Страница 4: ...er bracket 9070902 9070903 or spacer frame 9070906 9070907 for flexible installation as well as cable insertion from side or top bottom 230V Disconnect power source Make marks for the holes on the wal...

Страница 5: ...base Fasten base and spacer frame to the wall brown brown Phase Switched phase Neutral conductor Neutral conductor Earthing conductor Earthing conductor blue blue green yellow Connect the individual w...

Страница 6: ...lick Click Plug motion detector into base and click in Connect motion detector to power supply Dismantling Using the screwdriver carefully loosen the snap in hook at the side and pull the device forwa...

Страница 7: ...eflec tive surfaces such as mirrors etc Do not install motion detectors near heat sources such as heating outlets air conditioning systems lamps etc Do not direct the motion detector at objects that t...

Страница 8: ...e 150 180 5 Direction test and alignment The walk test is used to test the detection range and to res trict it if necessary Set the potentiometer time min to test The motion detector now only reacts t...

Страница 9: ...9 0 2 Sec 2 sec Test Min Align motion detector with sensor head The sensor head can be turned by 30 downwards and by 90 to left and right 30 30 30 90 90...

Страница 10: ...ux with the potentiometer If you want to change the preset brightness 15 lux default Set potentiometer to desired brightness 5 1000 lux teach in 1000 Lux 5 Lux 500 Lux 7 Lux 100 Lux 10 Lux 15 Lux 50 L...

Страница 11: ...0 5 s 20 min Min test 20 min 1 s 15 min 30 s 10 min 1 min 2 min 5 min 2 min If you want to use the pulse function e g for a staircase light time switch Set potentiometer to position Min The motion det...

Страница 12: ...60529 Switching capacity 10 A cos 1 6 A cos 0 6 3 AX cos 0 3 Min switching capacity 10 mA Switching contact Contact 230 V AC LED lamps 2 W 25 W LED lamps 2 W 8 W 90 W LED lamps 8 W 100 W Incandescent...

Страница 13: ...ddress Theben AG Hohenbergstr 32 72401 Haigerloch GERMANY Phone 49 7474 692 0 Fax 49 7474 692 150 Hotline Phone 49 7474 692 369 Fax 49 7474 692 207 hotline theben de Addresses telephone numbers etc ww...

Отзывы: