background image

6

Depending on the size of the room and the installed heating 

system, the bathroom reaches the desired 23 °C at 6.30 a.m., 

for example.

With a set optimisation of 5 min/K, the thermostat sends the 

heating request earlier, as follows:

Set temperature at 06.00 a.m. 

 23 °C

Actual temperature 

 17 °C

i.e. Delta T = 6 K

6 K * 5 min/K = 30 min

The controller sends the heating start 30 min. earlier and 

reaches the setpoint temperature at 06.00 a.m.

 

L

The optimisation value depends on the spatial and heating 

conditions.

5. Setting the error format

Error notifications from OpenTherm heaters can be received, 

depending on the manufacturer, in a hexadecimal or decimal 

format (see instructions for the OpenTherm heater).

6. Setting the chimney sweep function

This function is used to carry out the legally required emission 

measurements (off, partial load, full load). It is automatically 

switched off after 30 min.

7. Setting TSP parameters (Transparent Slave Parameters)

Depending on the connected OpenTherm heater, various 

TSP parameters can be set (see instructions for OpenTherm 

heater).

8. PIN

This function can be used to assign a new PIN.

 

The factory setting for the PIN is 0.

 

New PIN can be entered (1–6 digits).

 

In case of 

Delete pairing 

(2nd pairing), the PIN is set to 

0.

 

If the PIN is 0, the PIN will not be requested during 

pairing.

7.  Technical data

Supply voltage:

OT bus (approx. 50 mW)

Controller type:

modulating controller, works 

with OpenTherm proto-

col (OpenTherm V4.0 with 

SmartPower)

Temperature setting range: 

+ 2 °C ... + 30 °C in increments 

of 0.2 °C

Memory locations: 

42

Protection rating: 

IP 20 in accordance with EN 

60529

Protection class: 

III in accordance with EN 

60730-1

Operating temperature: 

+ 0 °C ... + 50 °C

Power reserve: 

4 hours

Mode of operation:

Type 1 STU in accordance with 

EN 60730-1

Rated impulse voltage: 

0.33 kV

Pollution degree: 

2

Software

Class A

8.  Contact

Theben AG

Hohenbergstr. 32

72401 Haigerloch

GERMANY

Phone +49 7474 692-0

Fax +49 7474 692-150

Hotline

Phone +49 7474 692-369

[email protected]

Addresses, telephone numbers etc. 

www.theben.de

Отзывы: