309 484 01

RAMSES 784 – HF Set 1 

784 9 407
784 9 417

    

Bedienungsanleitung

Uhrenthermostat

1

    

Operating Instructions

Clockthermostat

14

    

Mode d’emploi

Thermostat à horloge

26

    

Gebruiksaanwijzing

Klokthermostaat

38

    

Istruzioni d’uso

Cronotermostato

50

RAMSES 784 HF_309 484_D  25.02.2011  9:50 Uhr  Seite 1

Содержание RAMSES 784 HF

Страница 1: ...4 HF Set 1 784 9 407 784 9 417 Bedienungsanleitung Uhrenthermostat 1 Operating Instructions Clockthermostat 14 Mode d emploi Thermostat horloge 26 Gebruiksaanwijzing Klokthermostaat 38 Istruzioni d us...

Страница 2: ...pliance is switched on and off indepen dent of the radio transmitted room thermostat control signal Danger of death through electric shock or fire Installation should only be carried out by profession...

Страница 3: ...your heating 5 Ventilation apertures in the plinth 6 Setting normal temperature r day 7 Program selection switch normal operation in positionAUTO n or continuously normal r or energy saving operation...

Страница 4: ...ction 4 Fix the plinth to the wall approx 1 5 m above the floor if possible on an internal wall against which air can circulate without hindrance 5 Fit the clock thermostat to the plinth 6 Turn the se...

Страница 5: ...tops the heating switches on continuously but is not controlled Changing batteries 1 Take out the used batteries 2 Dispose of the batteries in an environmentally friendly way 3 Use only new similar ty...

Страница 6: ...ptional cases interference signals can be received from the surrounding area Depending on the strength of the interference several LEDS may be illuminated Align the antenna in such a way that as few L...

Страница 7: ...A Au ut to om ma at ti ic c Reception quality can if necessary be improved by the rod antenna available as acces sory equipment 4 Verifying codes Codierung Transmitting and receiving products are alr...

Страница 8: ...display on the receiver lights up briefly Test If you run the Coding function again the channel status display lights up as well as the level display 7 Response to a fault Transient malfunction The re...

Страница 9: ...back temperatur 20 C 16 C Manual switching override switching in place 2 in pos r the setting on rotary switch r 6 determines the temperature 2 in pos m the setting on rotary switch m 9 determines th...

Страница 10: ...appet onto 8 hours 22 5 5 m mi in n 2 20 0 m mi in n Dayprogram Product type RAMSES 784 HF can be switched from day to week program or vice versa Take off the graduated ring Turn the big hand until th...

Страница 11: ...iesafeingprogram r start comfortprogram m finish comfortprogram m start energiesafeingprogram r I In ns se er rt t a al lt te er rn na at te e m mo o I I t to o f fr r V V a red tappet at 4 AM and a b...

Страница 12: ...valve Pos 2 for slow mixing valve Pos 1 for floor heating bi metal mixer oil furnance 4 8 Adjustment of the operating point The clock thermostat is adjusted in the factory If re setting is necessary...

Страница 13: ...avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources we encourage you to use the appropriate take back systems Those systems will reuse...

Страница 14: ...henbergstr 32 72401 Haigerloch DEUTSCHLAND Fon 49 0 74 74 6 92 0 Fax 49 0 74 74 6 92 150 Service Fon 49 0 74 74 6 92 369 Fax 49 0 74 74 6 92 207 hotline theben de Addresses telephone numbers etc at ww...