3
595-5770-05
❒
When wiring to additional standard
fixture only: Strip the motion sensor's
red wire and connect to the standard
light's
black wire. Connect all white wires
together. Total fixture ratings must not
exceed 360 Watts (3.0 A.).
NOTE: All wiring between fixtures should
be run in accordance with the National
Electrical Code (Canadian Electrical Code
in Canada) through conduit or another
acceptable means.
Contact a qualified
electrician if there is any question as
to the suitability of the system.
OPTIONAL WIRING
❒
This fixture is provided with a sensor rated
for 360 Watts. Since the fixture is only
rated 100 Watts, 260 Watts of additional
load may be controlled by this sensor.
❒
When determining what a fixture is rated
for, do not simply look at the rating on the
lamp in the fixture. Look at the marking
which specifies the maximum lamp watt-
age for which the fixture is suitable.
❒
Once you have selected the fixtures
to be connected and determined their
maximum ratings, add these ratings up.
For instance, if you have 3 fixtures rated
100 Watts, 150 Watts, and 75 Watts re-
spectively, you have a total load of 325
Watts.
Wiring to Motion Light &
Standard Fixture
BLACK
WHITE
BLACK
(Standard)
RED
WHITE
BLACK
BLACK
Master
Slave
Wiring to Control One Motion Sensing
Lantern (Slave) from Another (Master)
RED
WHITE
WHITE