Electrical Specifications:

Supply Voltage.

10.2 to 40 VDC

Supply Current.

3mA (constant current) 

in all operational states

Environmental Specifications:

Temperature.

-10°C to +55°C

Humidity.

10 to 95% RH Non-condensing

Protection Index.

IP65 when suitably 

mounted and terminated

Mechanical Specifications:

Beam Head.

180mmH x 155mmW x137mmD 
Weight 1.1Kg

Controller. 

185mmH x 120mmW x 62mmD
Weight 0.55Kg

40KIT80 Mid-Range Reflector.

293mmH x293mmW x 5mmD 
Weight 0.8Kg

80KIT100 Long Range Reflector. 

394mmH x 394mmW x 5mmD 
Weight 1.8Kg

ADAPTER. 

270mmH x 250mmW x 5mmD 
Weight 0.6Kg 
(mounts the Beam Head onto unistrut)

Optical Specifications:

Optical Wavelength.

870nm

Maximum Angular Alignment.

±15°

Maximum Angular Misalignment.

(static not auto-aligning) 
Beam Head ±0.75° Reflector ±2°

Operational Specifications:

Protection Range:

FIREBEAM.

Standard Product 5 to 40 metres

40KIT80. 

Mid-Range Reflector Kit 40 to 80 metres

80KIT100.

Long Range Reflector Kit 80 to 100 metres

Alarm Sensitivity Levels:

25%(1.25dB) to 50%(3dB) in 1%(0.05dB) 
increments (default 35% (1.87dB))

Alarm Condition:

Obscuration drops to below pre-defined 
sensitivity level.

Time to Alarm Condition adjustable 
2 to 30 seconds in 1 second increments 
(default 10 seconds)

Alarm Indication:

Controller Status – FIRE

Controller Red Flashing LED 0.5 Second

Head Red Flashing LED 1 Second

Alarm Relay Change Over (CO) Contact

Rating 2A @ 30 VDC

Test/Reset Features:

Beam test function by controller

Alarm latching/auto-reset selectable 
(default auto-reset)

Alarm reset in latching mode by controller reset 
function, removing power for >5 seconds, 
apply 12 to 24 VDC to reset connections in
Beam Head.

Fault Sensitivity Level:

90%

Fault Condition:

Obscuration drops to below the fault 
sensitivity level within 1 second
Power Down or Supply Voltage < 9 VDC

Commissioning modes, Pre-Alignment 
and Auto Alignment

Beam turned off during Beam Maintenance 
(auto resets in 8 hours to normal)

Time to Fault Condition adjustable, 
2 to 60 seconds in 1 second increments 
(default 10 seconds)

Fault Indication:

Controller Status – FAULT

Controller Yellow Flashing LED 1 Second

Head Yellow Flashing LED 1 Second

Fault Relay Change Over (CO) Contact 
Rating 2A @ 30 VDC

Normal Condition:

Obscuration level is above the 
Alarm sensitivity level

Controller Status – NORMAL

Controller Green Flashing LED 1 Second

Programmable on/off

Head Green Flashing LED 1 Second

Programmable on/off

Auto-align/Beam Contamination 
Compensation:

Auto-align during normal operation if 
obscuration drops below 90%
(doesn’t effect normal operating mode)

Beam Contamination Compensation 4 hour 
monitoring. Compensation data available at 
the controller

technical specifications

Содержание firebeam

Страница 1: ...user guide issue 0025 05...

Страница 2: ...flector kit 5 40 metres the standard firebeam The standard firebeam comes boxed with the head unit low level controller one reflector 3mm allen key test filter and quick start installation guide this...

Страница 3: ...r side of the beam If the roof is considered to have an apex place thefirebeam system 0 3m to 0 6m down from the top of the apex up to a maximum height of 40m from the floor The maximum protected area...

Страница 4: ...first plugging in the connector step one mounting the head screw the head backing plate to the wall always try to use as sturdy location as possible such as brick or major structural steels avoid moun...

Страница 5: ...WN supply 10 2 30 Vdc BLUE supply return BLACK zone GREY zone GREEN earth screen Supply Voltage 12Vdc to 24 Vdc 25 15 Quiescent Current 3mA Alarm Current 3mA Aligning Current 3mA Fault Fire relay cont...

Страница 6: ...en the screen will default to 3 access the menu system by pressing enter 4 scroll through the menus until you get to commissioning 5 enter commissioning and enter pre alignment pre alignment is probab...

Страница 7: ...picking up a reflection from something other than the target blank wall By moving the beam looking at the wall left x right x up y and down y you can move the beam away any obstacles to achieve highe...

Страница 8: ...eing the reflector You will need to move the beam head until you receive an AQ reading of above 40 ideally over 100 If you are presented with the screen below AQ air quality could be any number up to...

Страница 9: ...greater air quality Wait for x y values to finish moving to asses your AQ result beam head reflector Press enter to exit manual mode and enter Auto Alignment Try and achieve as good a result as possi...

Страница 10: ...irebeam will automatically move its X and Y axis until it is positioned on the reflector This operation could take 30 minutes or more step four testing to test that the firebeam is aligned correctly y...

Страница 11: ...enter again to reset and return to the normal screen if in fire you will need to press back to go back to the main menu If set to auto reset it will reset to normal automatically no comms beam head i...

Страница 12: ...ss enter the power will slowly drop as can be seen in the dropping air quality When the air quality drops past the pre set threshold the beam will fall into fire remember that there is a delay time se...

Страница 13: ...in these directions across the face of the reflector with your back to the beam make adjustments by using the left right up and down keys this moves the beam in these directions across the face of the...

Страница 14: ...during auto alignment the alignment will be aborted press back to return to auto alignment and enter to resume auto alignment once alignment is complete you will see the screen below press back to ret...

Страница 15: ...xit sub menus shows temperature at beam head screen used by The Fire Beam help desk screen used by The Fire Beam help desk software versions for the head and controller shows when updating to increase...

Страница 16: ...n Controller Status FIRE Controller Red Flashing LED 0 5 Second Head Red Flashing LED 1 Second Alarm Relay Change Over CO Contact Rating 2A 30 VDC Test Reset Features Beam test function by controller...

Отзывы: