communication with the SDU to continue. This STBY mode can be obtained with four
configurations:
• Command configuration: In this case, an input command, Carriers Off/
Mute command from SDU, enable or disable the STBY mode
• Auto-protection configuration: When FMHPA detect an internal failure
(High level) and the SDU doesn’t answer within 2 seconds
• With carriers Off/Mute, the main characteristic of the mode is to have a
high isolation between FMHPA input and FMHPA output
• After HPA Power-On Self Test (POST) or at the end of a self test.
e.
BITE Monitoring
A monitoring Mode is defined in order to check if the FMHPA Status is OK or FAIL.
A self test is carried out at Start-up and on request from the SDU.
D. HPA Module
The HPA function is to amplify modulated signals from the SDU, up to 35 W.
The HPA includes an amplification chain, a digital part for control and communication
and a RF filter.
The output RF filter is a mechanical filter, without any electronic component, with a N
connector output.
E.
PSM and CM Module
The PSM and CM SRU module contains two modules in the same housing:
• Power Supply Module