2.1  MODELS AND TERMS

Tip Only: A nozzle without an integral ball shutoff  valve.
Ultimatic®  ER  Series:  Fog  and  straight  stream  monitor  nozzles  with  constant  pressure/variable  fl ow  control.    There  are  four 
diff erent pressure ranges. Electrically operated pattern control (with manual over-ride) adjusts from straight stream to 120° wide 
fog. The nozzle can fl ush large debris without shutting down.

B-TO-ERP WITH 6-PIN PLUG FOR TFT MONITORS

COUPLING

SERIAL NUMBER

STREAM
SHAPER

MANUAL
OVERRIDE KNOB

B745

10-125 GPM @ 100 PSI

40-500 LPM @ 6.8 BAR

VALPARAISO, IN 46383-9327 • +1 219 462-6161 • 800 348-2686

TASK FORCE TIPS ®

MADE IN U.S.A.

www.tft.com

MADE IN U.S.A.

www.tft.com

Understand manual before use. Obtain safety 

information at www.tft.com/serial-number

WARNING

PRODUCT LABEL

Figure 2.1 

Models and Terms

2.2 MECHANICAL SPECIFICATIONS

Weight

6.4 lbs

 2.9 kg

Hydrostatic burst pressure minimum

1200 psi

83 bar

Operating temperature range of fl uid

33 to 120º F

1 to 50º C

Storage temperature range

-40 to 150º F

-40 to 65º C

Actuation Force

173 lbs

 78.5 kg

Speed Stream-Fog

3.4 sec.

3.4 sec.

Materials used

Aluminum 6000 series hard anodized MIL8625 class 3 type 2, 

stainless steel 300 series, nylon 6-6, nitrile rubber

2.3 ELECTRICAL SPECIFICATIONS

Nominal operating voltage: 

12 or 24 VDC (auto sense)

Motor current:

Nominal*

Limit

@ 12 VDC

@24 VDC

@ 12 VDC

@24 VDC

Nozzle motor:

1 amp

0.5 amps

5 amps

2.5 amps

*with rated water pressure applied

Recommended fuse or circuit breaker size:

Refer to TFT Literature LIM-040 

Operating temperature range:

-30F to +120F (-34C to +49C)

Environmental Rating: 

All components designed to meet minimum rating of NEMA 4 (IP65).

Содержание Ultimatic ER

Страница 1: ...n who has not read and understood all operating and safety instructions is not qualified to operate the Ultimatic ER Nozzle Call 800 348 2686 with any questions This instruction manual is intended to familiarize firefighters and maintenance personnel with the operation servicing and safety procedures associated with the nozzle This manual should be kept available to all operating and maintenance pers...

Страница 2: ...UESTIONS 10 9 0 MAINTENANCE 10 9 1 LUBRICATION 10 9 2 SERVICE TESTING 10 9 2 1 HYDROSTATIC TESTING 10 9 2 2 FLOW TESTING 11 9 2 3 RECORDS 11 9 3 REPAIR 11 10 0 INSPECTION CHECKLIST 12 Copyright Task Force Tips LLC 2008 2019 LIY 500 April 8 2019 Rev14 MANUAL Remote Control RC Monitor Electrical Controls Supplemental Instructions for use with RC Monitor Manual INSTRUCTIONS FOR INSTALLATION SAFE OPER...

Страница 3: ...k to the nozzle will depend on the following factors Voltage of the line or equipment Distance from the nozzle to the line or equipment Size of the stream Whether the stream is solid or broken Purity of the water1 1 The Fire Fighter and Electrical Equipment The University of Michigan Extension Service Fourth Printing 1983 Page 47 CAUTION Fire streams are capable of injury and damage Do not direct ...

Страница 4: ...efore use Obtain safety information at www tft com serial number WARNING PRODUCT LABEL Figure 2 1 Models and Terms 2 2 MECHANICAL SPECIFICATIONS Weight 6 4 lbs 2 9 kg Hydrostatic burst pressure minimum 1200 psi 83 bar Operating temperature range of fluid 33 to 120º F 1 to 50º C Storage temperature range 40 to 150º F 40 to 65º C Actuation Force 173 lbs 78 5 kg Speed Stream Fog 3 4 sec 3 4 sec Materi...

Страница 5: ...am at a rapid enough rate Removal of empty foam containers Keeping clear path to deliver foam as hoses other equipment and vehicles are deployed WARNING Improper use of foam can result in injury or damage to the environment Follow foam manufacturer s instructions and fire service training to avoid Using wrong type of foam on a fire i e Class A foam on a Class B fire Plunging foam into pools of burnin...

Страница 6: ...10 25 50 75 GPM FLOW LPM FLOW 38 95 190 284 LBS REACTION 3 10 23 36 26 69 84 91 E 100 53 110 PSI INLET PRESSURE KGF REACTION 1 4 4 5 10 4 16 3 KGF CM 2 INLET PRESSURE 1 8 4 8 4 1 6 4 E 379 24 0 7 7 F 125 70 122 E 473 31 8 8 6 100 PSI ELECTRIC REMOTE CONTROL NOZZLE 60 50 40 40 30 20 20 10 0 0 80 100 120 140 A B C D E F These trajectories reach and reaction numbers are provided for reference All dat...

Страница 7: ... CURVE 10 25 50 75 GPM FLOW LPM FLOW 38 95 190 284 LBS REACTION 3 13 31 49 27 90 135 151 E 100 68 165 PSI INLET PRESSURE KGF REACTION 1 4 5 9 14 0 22 2 KGF CM 2 INLET PRESSURE 1 9 6 3 9 5 10 6 E 379 30 9 11 6 F 125 87 175 F 473 39 5 12 3 150 PSI ELECTRIC REMOTE CONTROL NOZZLE 60 50 40 40 30 20 20 10 0 0 80 100 120 140 A B C D E F These trajectories reach and reaction numbers are provided for refer...

Страница 8: ...uring flush the nozzle reaction decreases as the pattern becomes wider and the pressure drops The nozzle reaction increases when returning the nozzle from the flush position When used with a TFT RC Monitor equipped with Smart Stream technology the Fog button must be pressed and held a second time to reach the Flush position after having reached Full Fog The purpose of the Smart Stream feature is to ...

Страница 9: ...I 1 B820 ER 100 BARREL SUB ASS 120 PSI 1 B820 ER 120 BARREL SUB ASS 150 PSI 1 B820 ER 150 12 BARREL LABEL BLUE 1 B740 BARREL LABEL RED 1 B740 RED INDEX DESCRIPTION QTY PART NUMBER 13 O RING 030 1 VO 030 14 VALVE PLUG 1 B590 15 O RING 109 1 VO 109 16 I O SCREW 1 B595 17 7 32 TORLON BALL 4 V2130 TORLON 18 ER SHAPER GUIDE 1 B514 19 NAME LABEL BLUE 75 PSI 1 B745F NAME LABEL RED 100 PSI 1 B745 NAME LAB...

Страница 10: ...een repaired or altered by someone else THIS IS A LIMITED EXPRESS WARRANTY ONLY TFT EXPRESSLY DISCLAIMS WITH RESPECT TO THE EQUIPMENT ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE THERE IS NO WARRANTY OF ANY NATURE MADE BY TFT BEYOND THAT STATED IN THIS DOCUMENT This limited warranty gives you specific legal rights and you may also have oth...

Страница 11: ...ire hose couplings nozzles and fire hose appliances 2013 ed Section 5 5 4 Quincy MA National Fire Protection Agency 9 3 REPAIR Factory service is available with repair time seldom exceeding one day in our facility Factory serviced nozzles are repaired by experienced technicians to original specifications fully wet tested and promptly returned Repair charges for non warranty items are minimal Any re...

Страница 12: ...tion if applicable 9 There is no damage to the nozzle tip 10 The shut off valve if so equipped operates as designed and shuts the flow off completely BEFORE BEING PLACED BACK IN SERVICE nozzles must be inspected to this checklist 1 All controls and adjustments are operational 2 Shut off valve if so equipped closes off the flow completely 3 There are no broken or missing parts 4 There is no damage to the...

Отзывы: