©Copyright Task Force Tips LLC 2017-2018
LIY-210 September 17, 2018 Rev01
14
5.0 OPERATION OF RC MONITORS
See Remote Control (RC) Monitor Electrical Controls Supplemental Instructions LIY-500 for operation of the EF1 RC Monitor. See
LIY-700 for BlueTooth controller operation instructions.
6.0 RECOMMENDED PARK POSITION
For truck mounted applications it is recommended that the monitor be parked in a position such that the monitor’s nozzle rests
against a bracket or support surface. If a support surface is not available, run the elevation against one of its travel stops to take some
of the backlash out of the gear drive. This will minimize bouncing of the nozzle when the apparatus is traveling. Always be sure the
monitor is properly parked before moving the truck and know the overall height to avoid damage from overhead obstructions such
as doors or bridges. See Remote Control (RC) Monitor Electrical Controls Supplemental Instructions (LIY-500) for information on
programming, OSCILLATE and PARK position of the EF1 RC monitor.
6.1 OVERRIDE HEX DRIVE
In the event of electrical system failure on the monitor or fi re truck, the EF1 RC Monitor is factory supplied with a hex drive so a 1/4”
hex wrench may be used for manual override. Pry the dust caps off from the horizontal or vertical shafts to access the hex drives.
¼” Hex Wrench
Understand manual before use. Operation of this device
without understanding the manual and receiving proper training is a misuse of
this equipment. Obtain safety information at www.tft.com/serial-number
ZB1069
WARNING
®
www.tft.com
Y5703
Fig 6.1
Wrenching Hexes on Drive Shafts