21 

 

The PSW-2G+ has 54V DC backup power. The supply cable is brought into 
the unit through the cable gland and connected to the terminal block on the 
switch circuit board. Calculation of the cable cross-section is based on the 
maximum consumption that does not exceed 250W. 

IMPORTANT! 

The switch can be operated without a backup power supply. 

 

6.4  Connection of video cameras 

To the ports FE, connect cameras using a twisted pair. It is recommended 
to  use  a  4-pair  shielded  cable  no  worse  than  Category  5.  The  PSW-2G+ 
allows  you  to  connect  any  PoE  video  camera  with  one  cable,  which 
drastically reduces the complexity of system installation. 
The Ethernet cable is inserted through the cable gland into the unit, clipped 
and connected to the FE ports. For the convenience of clipping, it is allowed 
to  remove  the  cable  gland  from  the  unit  and  then  re-install  it  back  to  its 
original state. Unused cable glands should be closed off. 

RJ-45 

RJ-45 

 

Figure 6.4. Fanning out of the Ethernet cable. 

 

7 Manufacturer

’s warranty 

Warranty period for the device 

– 36 months from the sale date. The device 

is accepted for warranty maintenance and repair only in full kit. 
Warranty repair is not performed in following cases: 

•  if warranty period has expired; 

•  if  there  is  no  label  with  serial  number  on  the  product  housing,  and 

also if serial number was changed, removed or illegible; 

•  if there are external and internal mechanical damages (chips, cracks, 

deformation,  damage  to  the  power  cord,  breaks  and  cracks  of 
connectors),  traces  of  chemicals,  corrosive  environments,  liquids, 
heavy contamination, as well as the presence of insects or traces of 
their presence; 

White Orange 

White orange 

Orange 

White Green 

Blue 

White Blue 

Green 

White Brown 

Brown 

Orange 

White Green 

Blue 

White Blue 

Green 

White Brown 

Brown 

Содержание PSW-2G+

Страница 1: ...1 Operation Manual PSW 2G Multifunction Gigabit Managed Switch with PoE IEEE802 3at for IP video surveillance systems Version 6...

Страница 2: ...NTION If mode PoE_B Passive is active at the port connect computer to it only by 4 wire 2 paired Ethernet cable ATTENTION Max load over PoE must be less than 160W ATTENTION SFP port operates only at 1...

Страница 3: ...ote polling of video cameras 15 2 9 Power supply backup 14 3 Technical parameters 16 4 Operation conditions 16 5 Presetting 17 5 1 Restore switch to Factory Settings 17 5 2 Setting the IP address 17 5...

Страница 4: ...perature range Using industrial SFP modules in industrial version guarantees operation from 55 C to 70 C 67 to 158F The maximum temperature depends on the load see diagram in section 4 Operation condi...

Страница 5: ...ning protection of Ethernet ports and 220V PSU reliably protects both the switch and connected video cameras from pulse disturbances induced by lightning discharges Cold start Preheating of camera hou...

Страница 6: ...6 2 Description 2 1 Appearance Figure 2 1 1 PSW 2G outside view Figure 2 1 2 PSW 2G inside appearance...

Страница 7: ...7 Figure 2 1 3 PSW 2G disassembled...

Страница 8: ...8 2 2 Element arrangement Figure 2 2 Element arrangement of the PSW 2G...

Страница 9: ...came possible to power any PoE video camera over simple Ethernet cable This is implemented as follows Over pairs of wires 1 2 and 3 6 mode A is transmitted 30W and over pairs 4 5 and 7 8 mode B is als...

Страница 10: ...wer according to mode B to the Passive PoE mode via the WEB interface on the Port Settings tab In this case the video camera will be powered according to mode A and the camera housing will be powered...

Страница 11: ...ally operated sealed switches and end switches optical switch is more reliable It does not stick does not give a rattling An operating principle is simple When the unit is closed special detector Figu...

Страница 12: ...ifferential electromagnetic disturbances Switches are resistant to high energy microsecond pulse interference in accordance with GOST R 51317 4 5 standard with a degree of rigidity according to Table...

Страница 13: ...t Degree of rigidity according to the table 1 GOST R 51317 4 5 Voltage pulse value kW 10 Power lines of the switch wire wire 3 2 Power lines of the switch wire ground 4 4 Symmetrical communication lin...

Страница 14: ...PSW 2G switch constantly 1 time per minute monitors the Link signal from the IP camera If the switch does not detect the Link signal then it starts a one minute timer when it ends the connection is re...

Страница 15: ...ta 1 2 3 6 Please note that the accuracy of the cable tester is 2 meters By default VCT operates on an average algorithm and does not take into account the specific features of a particular cable whic...

Страница 16: ...ion distance up to 100m Main power supply unit supply voltage 220V from 187V to 246V max power consumption not more than 200W Backup power supply unit supply voltage 54V DC from 53V to 55V max power c...

Страница 17: ...managed from remote stations anywhere in the network via a standard Web browser for example Microsoft Internet Explorer The browser is a universal access tool and can directly access the PSW 2G using...

Страница 18: ...camera installed into the TFortis TH camera housing you must set the PoE_A Auto PoE_B Passive via the WEB interface on the Port Settings tab The video camera will be powered as the option A and the c...

Страница 19: ...you connect switches into a ring then you need to enable the RSTP protocol Otherwise if alternative paths appear your network will not work By default RSTP is disabled 6 Device installation 6 1 Unit m...

Страница 20: ...er connection 6 3 1 Main power supply The PSW 2G is connected to the AC source of 220V The supply cable is brought into the unit through the cable gland and connected to the terminal block of the powe...

Страница 21: ...llowed to remove the cable gland from the unit and then re install it back to its original state Unused cable glands should be closed off RJ 45 RJ 45 Figure 6 4 Fanning out of the Ethernet cable 7 Man...

Страница 22: ...ompliance with the rules of connection and operation as well as non compliance of power specified in the operating manual due to force majeure third party action and other reasons that doesn t depend...

Отзывы: