Schedule
Power consumption calculation
Power consumption of TFortis PSW switch is calculated by the following formula
)
(
TP
TH
CAM
SW
P
P
P
P
P
SW
P
For the switch itself power consumption is not more than 5W.
CAM
P
Power consumption of video camera.
TH
P
Power consumption of the heater of the thermal housing taking into
account losses in twisted pair. Not more than 12W.
TP
P
losses in twisted pair when supplying power to the video camera
PSU efficiency of TFortis PSW (at least 85%)
Note 1
For some video cameras the manufacturer specifies PoE rating but not power. In
this case, to determine
CAM
P
, follow the table below.
Energy class
Max power, W
Class 0 and Class 3
13
Class 1
3.84
Class 2
6.49