background image

 

 

 

23 

 

Drilling  of  the  housing  will  lead  of  loss  of  the  switch 
integrity and, as a result, loss of product warranty. 

 
 
 

7.1 Installation of the cabinet on poles 

To mount the cabinet on the pole, use TFortis-1 Attachment Set for square and 
round posts. 
 

 

Figure 7.2 - TFortis-1 Attachment Set. 

 

The Attachment Set is not included in the supply scope. 

 
 

7.3 Optical connections 

The  switch  has  an  optical  distribution  frame.  For  ease  of  operation  the  optical 
distribution frame can be removed from the cabinet. The optical cable is pulled 
into PG13.5 cable glands. The optical cable is attached to the metal base of the 
distribution  frame  with  nylon  ties  or  metal  cable  ties.  To  fix  the  optical  cable 

Содержание PSW-1G4F-Box

Страница 1: ...Multifunction Gigabit Managed Switch with PoE support IEEE802 3af for IP Video Surveillance Systems PSW 1G4F Box Operating Manual Version 1...

Страница 2: ...computer to the switch remove PoE jumpers for this port SFP port operates only at 1000 Mbps Fast Ethernet SFP modules will not operate For effective lightning protection the following is required pro...

Страница 3: ...breaker 16 3 10 Additional functions 16 3 10 1 Cold start 16 3 10 2 Restarting cameras in case of hanging 16 3 10 3 Cable tester 17 3 10 4 Remote camera polling 18 4 Technical specifications 18 5 Oper...

Страница 4: ...4 1 Purpose PSW 1G4F Box is a multifunction gigabit outdoor managed switch used for the construction of IP video surveillance networks Figure 1 PSW 1G4F Box connection scheme...

Страница 5: ...ation 1000 M or 100 M Use a jumper to select a managed mode MAN or an unmanaged mode UNMAN The unmanaged mode does not require any additional configuration of the switch but it has fewer functions It...

Страница 6: ...illance networks Two 1 gigabit ports allow to connect switches in a chain Support of STP RSTP protocols allows to create ring topologies which significantly improves fault tolerance of the system The...

Страница 7: ...7 3 Description 3 1 Appearance Figure 3 1 1 PSW 1G4F Box external appearance Figure 3 1 2 PSW 1G4F Box interior...

Страница 8: ...ss filled polycarbonate IK10 impact protection rating due to fiber glass reinforcement Dust and moisture protection IP66 Fire resistance UL94 5VA Electrical insulation 1500VDC UV resistance UL 508 3 3...

Страница 9: ...9 3 4 Switch board and power supply units Figure 3 4 1 Switch board and power supply units Figure 3 4 2 Layout of components inside PSW 1G4F Box...

Страница 10: ...pairs 1 2 and 3 6 over data Option A or by free pairs 4 5 and 7 8 Option B Table 3 4 1 Configuration of PoE jumpers Pairs 1 2 and 3 6 Option A Pairs 4 5 and 7 8 Option B Item IEEE802 3af video camera...

Страница 11: ...11 Figure 3 4 3 Power supply scheme over PoE for different variants...

Страница 12: ...O position make sure that when you connect devices that do not support PoE for example a PC PoE jumpers for the corresponding port IV are removed see Section 3 4 1 3 4 3 CPU button To restart the swit...

Страница 13: ...ence of supply voltage on the switch boards 3 5 Dry contact On the switch board there is a dry contact SENSOR 1 digital input This port can be used to connect a relay output of the user equipment Its...

Страница 14: ...to be sent to the server via SNMP Traps SMTP or Syslog protocols see detailed information in the Configuration Manual Figure 3 6 1 Tamper sensor on the switch cover Figure 3 6 2 Tamper sensor on the...

Страница 15: ...microsecond pulse interferences according to GOST R 51317 4 5 standard as per Table 3 7 1 with performance criteria B temporary disruption of performance or functioning with further recovery without o...

Страница 16: ...the camera housing 1 hour later the camera itself it supplied This delay provides comfortable conditions for the camera start and prevents failures of expensive equipment The Comfort Start option is a...

Страница 17: ...once the switch makes a decision that the camera is functional and starts the poll cycle again polling the camera 1 time per minute The Auto Restart option is available via the web interface in the S...

Страница 18: ...h it is possible to ping any device on the network through the web interface which is convenient when solving network problems 4 Technical specifications Gigabit Ethernet ports 1000Base X with SFP con...

Страница 19: ...itions at an ambient temperature from minus 60 to plus 50 C and above with the use of industrial SFP modules The switch remains fully functional after exposure to ambient temperatures from minus 60 C...

Страница 20: ...ct any switch port to an Ethernet network Keep in mind that in case the device is configured over a network the IP address of the management workstation should belong to the same IP network For exampl...

Страница 21: ...vices that do not support PoE for example a PC PoE jumpers for the corresponding port are removed 6 5 Switching on camera housing preheating When the camera is started in freezing weather it can fail...

Страница 22: ...hs your network will not be functional By default RSTP is turned off 7 Installation of the switch 7 1 Installation of the cabinet on the wall The cabinet has four attachment points that do not contact...

Страница 23: ...sts Figure 7 2 TFortis 1 Attachment Set The Attachment Set is not included in the supply scope 7 3 Optical connections The switch has an optical distribution frame For ease of operation the optical di...

Страница 24: ...the use of optical patch cords It is allowed to connect the pigtails directly to SFP without any unnecessary connections Nylon ties shrinkable plastic sleeves pigtails and adapters are not included in...

Страница 25: ...ly Grounding of the switch is mandatory Grounding resistant should not exceed 4 Ohm 7 5 Camera connection Camera connection recommendations 1 Use a 4 pair shielded twisted pair at least category 5 2 U...

Страница 26: ...anical damages chipping cracking deformation damaged power supply wires cracking or splitting of the terminals signs of treatment with aggressive chemicals or fluids severe contamination insects prese...

Страница 27: ...la TP TH CAM SW P P P P P SW P For the switch itself power consumption is not more than 5W CAM P Power consumption of video camera TH P Power consumption of the heater of the thermal housing taking in...

Страница 28: ...te 3 TH P not considered when outdoor cameras are used as the manufacturer specifies the total consumption of the camera and the housing Example It is required to calculate power consumption of TForti...