Thank you for choosing this instrument from TFA. 

1. Before you use this product

Please make sure you read the instruction manual carefully. 

This information will help you to familiarize yourself with your new device, to learn all of its functions
and parts, to find out important details about its first use and how to operate it and to get advice in the
event of a malfunction.

Following and respecting the instructions in your manual will prevent damage to your instrument and
loss of your statutory rights arising from defects due to incorrect use. 

We shall not be liable for any damage occurring as a result of non following of these instructions.
Likewise, we take no responsibility for any incorrect readings or for any consequences resulting from
them.

Please take particular note of the safety advice!

Please keep this instruction manual safe for future reference.

2. Delivery contents

• CO

2

Monitor

• USB cable
• Instruction manual

Diese Anleitung oder Auszüge daraus dürfen nur mit Zustimmung von TFA Dostmann veröffentlicht werden. Die techni-
schen Daten entsprechen dem Stand bei Drucklegung und können ohne vorherige Benachrichtigung geändert werden.
Die neuesten technischen Daten und Informationen zu Ihrem Produkt finden Sie auf unserer Homepage unter Eingabe der
Artikel-Nummer in das Suchfeld.

www.tfa-dostmann.de

E-Mail: [email protected]

TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, D-97877 Wertheim, Deutschland

12/20

TFA_No. 31.5009_Anleit_12_20  17.12.2020  18:22 Uhr  Seite 9

Содержание AIRCO 2 NTROL COACH

Страница 1: ...lt of non following of these instructions Likewise we take no responsibility for any incorrect readings or for any consequences resulting from them Please take particular note of the safety advice Please keep this instruction manual safe for future reference 2 Delivery contents CO2 Monitor USB cable Instruction manual Diese Anleitung oder Auszüge daraus dürfen nur mit Zustimmung von TFA Dostmann v...

Страница 2: ...ns and Electro Static Discharge Readings may be affected if the unit is operated within a radio frequency elec tromagnetic field strength of approximately 3 volts per meter The performance of the instrument will not be permanently affected 3 Range of application and all the benefits of your new instrument at a glance For monitoring the CO2 concentration in buildings where people are present eg sch...

Страница 3: ...s to normal mode to confirm the setting The following four settings are available 7 1 1 Auto default In this mode the display colour changes automatically in smooth transitions between the 3 colour shades depending on the current reading of the CO2 levels Green Optimal air quality The CO2 concentration is below 800 ppm Yellow Medium air quality The CO2 concentration is between 800 ppm and 1400 ppm...

Страница 4: ...atically quit the setting mode if no button is pressed for 20 seconds 8 Display section HISTORY The graph shows the measured CO2 values of the last 24 hours clearly The bar on the position 0 h always corresponds to the current measured value of the CO2 level the bar is updated every 10 seconds together with the measured value 7 1 2 AL In this mode the red display illumination is activated as an op...

Страница 5: ...USB USB cable included The bar 3 corresponds to the average of the CO2 levels of the last 3 hours The bar 6 corresponds to the average value of the CO2 levels for the period between 3 to 6 hours The bar 12 corresponds to the average value of the CO2 levels for the period between 6 to 12 hours The bar 18 corresponds to the average value of the CO2 levels for the period between 12 to 18 hours The ba...

Страница 6: ...d in our homepage by simply entering the product number in the search box www tfa dostmann de E Mail info tfa dostmann de TFA Dostmann GmbH Co KG Zum Ottersberg 12 D 97877 Wertheim Germany 12 20 CO2 Measuring range 0 9999 ppm Resolution 1 ppm Accuracy 7 or 100 ppm at 0 3000 ppm whichever is greater 10 at 3000 ppm Update interval 10 seconds Warm up time approx 10 seconds Method Non Dispersive Infra...

Отзывы: