background image

 

71

order to protect the environment. 
The symbols for the heavy metals contained are: Cd=cadmium, Hg=mercury, Pb=lead 

 

 

This instrument is labelled in accordance with the EU Waste Electrical and 
Electronic Equipment Directive (WEEE).  
Please do not dispose of this product with other household waste. The user 
is obligated to take end-of-life devices to a designated collection point for the 
disposal of electrical and electronic equipment, in order to ensure 
environmentally-compatible disposal.  

 

 

TFA Dostmann GmbH & Co. KG, Zum Ottersberg 12, D - 97877 Wertheim 
No part of this manual may be reproduced without written consent of TFA Dostmann. The 
technical data are correct at the time of going to print and may change without prior notice. 
 

DECLARATION OF CONFORMITY 

Herewith we declare, that this wireless transmission device does comply with the essentials 
requirements of R&TTE Directive 1999/5/EC. 
A copy of the signed and dated Declaration of Conformity is available on request via 
[email protected]
www.tfa-dostmann.de 
06/12 

Содержание 30.3032

Страница 1: ...hasing this compact 868MHz Temperature Station which displays radio controlled time date indoor and outdoor temperature In addition the daily minimum and maximum indoor and outdoor temperature are sho...

Страница 2: ...40 FEATURES The Temperature Station Foldout Stand Battery compartment cover Function Keys LCD Display Hanging hole...

Страница 3: ...oor signal reception intervals at 4 second Temperature display in degrees Celsius C or Fahrenheit F selectable Indoor and Outdoor temperature display with MIN MAX recording records can be reset Can re...

Страница 4: ...casing Wall mounting and table stand DUAL CHANNEL TRANSMITTER There are an internal channel and an external probe channel in the transmitter The data measured by the internal sensor and the measuring...

Страница 5: ...after initial setup There is no need to reset the units should the probe be unplugged or re plugged again The Temperature Station will automatically detect the temperature probe data and will display...

Страница 6: ...nternal sensor of the dual channel transmitter Channel 2 will show the reading sensed by the probe If the probe is not plugged to the transmitter will be shown on Channel 2 5 In order to ensure suffic...

Страница 7: ...after 2 minutes the batteries will need to be removed from both units and reset from step 1 5 Insert the batteries into the second transmitter as soon as the outdoor temperatures from the first trans...

Страница 8: ...followed as described above Should transmission problems occur it is necessary to remove the batteries from all units and follow the set up from step 1 If after 10 minutes the Atomic auto set time DC...

Страница 9: ...ries please follow the steps below 1 Remove the cover at the back of the Temperature Station 2 Insert batteries observing the correct polarity see marking 3 Replace compartment cover INSTALL AND REPLA...

Страница 10: ...he setting up procedures This is because a random security code is assigned by the transmitter at start up and this code must be received and stored by the Temperature Station in the first 3 minutes o...

Страница 11: ...d hold to enter the setting mode for the following settings LCD contrast Time zone Atomic Time Reception RCC ON OFF 12 24 hr format Manual time Year Month Day and C F settings MIN MAX key To toggle be...

Страница 12: ...evel key To make a positive adjustment for various settings In normal display press to toggle between the display of the calendar data and second of time in the time display of LCD CH key To make a ne...

Страница 13: ...Exteriores Daily indoor max temp Daily indoor min temp Icono interior Channel No Outdoor Sensor ID Time reception icon Outdoor signal reception icon Weekday Day or Day Month or Second display Daily o...

Страница 14: ...tter No will be shown when more than one outdoor transmitter is adopted For better distinctness the LCD screen is split into 3 sections displaying the information for time and date Indoor data and out...

Страница 15: ...on receives this signal and converts it to show the precise time in summer or wintertime The quality of the reception depends greatly on the geographic location In normal cases there should be no rece...

Страница 16: ...the unit close to a window and or point its front or back towards the Frankfurt transmitter MANUAL SETTINGS The following manual settings can be done in the setting mode LCD Contrast setting Time zone...

Страница 17: ...rast desired 2 Press the SET key to confirm and enter the Time Zone setting or exit the setting mode by pressing the MIN MAX key TIME ZONE SETTING The time zone default of the Temperature Station is 0...

Страница 18: ...n the LCD 2 Use the key or CH key to turn OFF the time reception function 3 Confirm with the SET key and enter the 12 24 Hour Display setting or exit the setting mode by pressing the MIN MAX key Note...

Страница 19: ...mat will be date and month display When 12 h mode display is selected the calendar format will be month and date display MANUAL TIME SETTING In case the Temperature Station is not able to detect the A...

Страница 20: ...1 1 of the year 2006 after initial set up Once the radio controlled time signals are received the date is automatically updated However if the signals are not received the date can also be set manuall...

Страница 21: ...the month and day value is input C F TEMPERATURE UNIT SETTING The default temperature reading is C degree Celsius To select F degree Fahrenheit 1 The C or F will be flashing use the key or CH key to...

Страница 22: ...SPLAY OF INDOOR MINIMUM AND MAXIMUM RECORDS 1 In normal display mode press the MIN MAX key once the minimum indoor temperature will be shown in LCD Also the time and date of recording this temperature...

Страница 23: ...displayed 3 Press three more time the MIN MAX button to go back to the normal display DISPLAY OF OUTDOOR MINIMUM AND MAXIMUM RECORDS 1 In normal display mode Press the MIN MAX button three times the o...

Страница 24: ...be displayed 3 Press one more time the MIN MAX button to go back to the normal display RESETTING THE INDOOR AND OUTDOOR MINIMUM MAXIMUM RECORDS 1 In normal display mode press the MIN MAX button once...

Страница 25: ...ecord as well as the minimum and maximum records of all outdoor channels will be reset at the same time DAILY INDOOR MIN AND MAX TEMPERATURE DISPLAY This temperature station shows the daily minimum an...

Страница 26: ...us channel display Note The MIN MAX outdoor temperature resolution is 0 5 C The daily minimum temperature record is reset automatically at 8 00 pm and the daily maximum temperature is reset automatica...

Страница 27: ...ors using electrical devices operating on the 868MHz signal frequency can also cause interference Note When the 868MHz signal is received correctly do not re open the battery cover of either the trans...

Страница 28: ...outdoor temperature values can be received from the desired locations 1 Fix a screw not supplied into the desired wall leaving the head extended out the by about 5mm 2 Remove the stand from the Tempe...

Страница 29: ...e bottom to the transmitter To wall mount 1 Secure the bracket onto a desired wall using the screws and plastic anchors 2 Clip the transmitter onto the bracket Note Before permanently fixing the trans...

Страница 30: ...es to avoid leakage and damage Replace only with new batteries of the recommended type Do not make any repair attempts to the unit Return them to their original point of purchase for repair by a quali...

Страница 31: ...Alkaline batteries recommended Temperature Station Approximately 12 months Temperature Transmitter Approximately 12 months Dimensions L x W x H Temperature Station 95 x 18 8 x 136 mm Temperature Trans...

Страница 32: ...rrect readings and any consequences that occur should an inaccurate reading take place This product is designed for use in the home only as indication of the temperature and other weather data This pr...

Страница 33: ...d electronic equipment in order to ensure environmentally compatible disposal TFA Dostmann GmbH Co KG Zum Ottersberg 12 D 97877 Wertheim No part of this manual may be reproduced without written consen...

Отзывы: