HALO FORKHEAD INSTRUCTIONS

(Models 8281 and 9391)

The operational performance of the forkhead is the
same as the hookhead, but offers a slightly different
approach in obtaining current measurements. All
safety concerns that apply to the hookhead apply to
the forkhead. The positioning of the instrument with
respect to the conductor and the positioning of the
conductor within the forkhead is critical in obtaining
an accurate reading. To obtain the most accurate
reading, the following guidelines should be observed.

1. Be sure the HALO body is perpendicular (90°) to the

conductor (reference Figures 3, 4, 5 and 6 on page 5).

2. If there are other conductors in close proximity,

face the opening of the fork away from the other
conductor(s) as much as possible.

3. Position the forkhead so the conductor is close to, or

pressed against, the base of the fork and is centered
between the legs of the fork (See Figure 8).

4.  Keep the opening of the forkhead perpendicular

to the conductor (See Figure 9).

WARNING

- Do not bridge the HALO from energized line to ground or from line to line.

NOTE

- When using the forkhead on underground systems near the elbow, the concentric

neutral cannot be inside the forkhead for the unit to perform properly. Position the forkhead
around the conductor where the concentric neutral is peeled back. This is usually high on
the cable, just below the elbow or on the elbow below the pulling ground.

SPECIFICATIONS AND DIMENSIONS

Display:

3.5 digit LCD 1⁄2” (13mm) high characters

Measurement Range:

0.1 to 199.9 amps low range - 199.9 to 1,999 amps high range

Accuracy:

+/- 3% of r/- 3 counts 

Operating Temperature:

0°F to 122°F (-18°C to 50°C)

Storage Temperature:

0°F to 122°F (-18°C to 50°C)

System Voltage:

Up to 69,000 volts AC

Operating Frequency:

25-1000Hz

Maximum Hook Opening:

2.3” (5.8cm)

Maximum Hook Depth:

3.7” (9.4cm)

Outside Fork Dimension:

5.5”W x 8.5”L x 1.1875” Thick (14cm x 22cm x 3cm)

Inside Fork Dimension:

2.75”W x 5.5” Deep (7cm x 14cm)

Overall Length:

28” (71cm)

Tube Dimensions:

18” x 1-3⁄4” (45.7cm x 4.5cm) diameter

Weight:

2lbs. 13oz. (1.28 kg)

*Specifications subject to change without notice

Figure 8

Figure 9

Содержание HDE HALO

Страница 1: ...ng Instruction Manual HALO AMMETER ModelNumbers 8280 8281 9390 9391 1475 Lakeside Drive Waukegan Illinois 60085 U S A 847 473 4980 fax 847 473 4981 website www HDElectricCompany com https www tequipme...

Страница 2: ...DESCRIPTION 3 SAFETY 3 DESCRIPTION OF EQUIPMENT 3 USING THE EQUIPMENT 4 HALO BATTERY REPLACEMENT 5 HALO FORKHEAD INSTRUCTIONS 6 LIMITATION OF WARRANTY AND LIABILITY 8 Operating Instruction Manual HAL...

Страница 3: ...voltage equipment please practice the following safety precautions 1 Before use make certain that A Operating instructions are read understood and questions answered B Rigorous hotstick work precautio...

Страница 4: ...22 lbs 10kg longitudinal or 11 lbs 5kg in any other direction 3 Turn the HALO on by pressing the ON RESET switch HALO I or ON OFF switch HALO II for approximately 5 seconds While the button is depres...

Страница 5: ...blank HALO BATTERY REPLACEMENT NOTE Figure7showsacrosssectionalviewofthebatteryholder 1 Place the HALO horizontally 2 The Battery Holder is attached to the body by two brass screws 4 screws on some v...

Страница 6: ...lar to the conductor See Figure 9 WARNING Do not bridge the HALO from energized line to ground or from line to line NOTE When using the forkhead on underground systems near the elbow the concentric ne...

Страница 7: ...Battery indication on Display Replace battery if needed before using Moldedplastichead guides conductorinproperposition eliminatingerrorsdue tovaryingconductor sizesandlocations Epoxyencapsulated sens...

Страница 8: ...ete unavailable over time end of life In the event that a Product cannot be repaired or replaced due to unavailability of parts HD Electric Company will use commercially reasonable efforts to obtain s...

Отзывы: