RK1240 and RK1240C Crimping Tools
Greenlee / A Textron Company
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
7
Operation
Electrical shock hazard:
This tool is not insulated. When using
this unit near energized electrical
lines, use only certified non-con-
ductive hoses and proper personal
protective equipment.
Failure to observe this warning could
result in severe injury or death.
Pinch points:
Keep hands away from closing dies.
Failure to observe this warning could
result in severe injury or death.
Note: When using KC12-type dies, complete the
number of crimps listed on the “Connector Selection”
chart in this manual. For other dies, complete the
number of crimps specified by the manufacturer.
1. Prepare the cable by stripping off the appropriate
amount of insulation.
2. Select a connector that corresponds to the conduc-
tor and the application.
3. Insert the conductor into the connector. Position the
connector as shown.
4. Activate the hydraulic power source until the ram
has advanced and the crimp is completed.
Note: To assure a complete crimp, verify that the
power source has reached 700 bar (10,000 psi).
Refer to the “Periodic Relief Valve Check” in this
manual.
5. Stop the power source and allow the ram to retract.