16
Typical Measurements and Accuracy
(cont’d)
Ω
Resistance
Measurement
SELECT
Continuity Check
Resistance
Range
Accuracy
600.0 Ω
± (1.0% + 0.5 Ω)
6.000 kΩ
± (1.0% + 0.005 kΩ)
60.00 kΩ
± (1.0% + 0.05 kΩ)
Open Circuit Voltage: 1.0 VDC
Continuity
Tone Threshold: Between 10 Ω and 250 Ω
Response Time: Approximately 32 ms
Capacitance
Measurement
Capacitance (CM-860, CM-960,
CMH-600, and CMI-600 only)
Range
Accuracy*
200.0 μF
± (2.0% + 0.4 μF)
2500 μF
± (2.0% + 4 μF)
* For film capacitors (capacitors with
negligible dielectric absorption).
Note: For polarized capacitors, attach red
probe to positive terminal and black probe to
negative terminal of capacitor.
Содержание Greenlee CM-660